MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1378/chest.121.1.189

Медицинская библиотека · Chest · 2002

Iron lung vs mask ventilation in the treatment of acute on chronic respiratory failure in COPD patients: a multicenter study.

Corrado Antonio, Confalonieri Marco, Marchese Santino, Mollica Corrado, Villella Giuseppe, Gorini Massimo, Della Porta Rossana

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

STUDY

OBJECTIVES

Evaluation of the effectiveness of negative-pressure ventilation (NPV) with the use of the iron lung vs noninvasive positive-pressure ventilation (NIPPV) in the treatment of COPD patients with acute on chronic respiratory failure.

DESIGN

A retrospective case-control study.

SETTING

Four Italian respiratory intermediate ICUs.

PATIENTS: Of a total of 393 COPD patients admitted to the ICU in 1996, 53 pairs were treated with the iron lung (NPV group). Patients treated with NIPPV (NIPPV group) were matched according to mean (+/- SD) age (70.3 +/- 7.1 vs 70.3 +/- 6.9 years, respectively), sex, causes of acute respiratory failure (ARF), APACHE (acute physiology and chronic health evaluation) II score (22.4 +/- 5.3 vs 22.1 +/- 4.6, respectively), pH (7.26 +/- 0.05 vs 7.27 +/- 0.04, respectively), and PaCO(2) (88.1 +/- 11.5 vs 85.1 +/- 13.5 mm Hg, respectively) on admission to the ICU. The effectiveness of matching was 98.4%.

RESULTS

Five patients from the NPV group (9.4%) and seven patients from the NIPPV group (13.2%) needed endotracheal intubation (EI). The treatment failure rate (ie, death and/or need of EI) was 20.7% in the NPV group and 24.5% in the NIPPV group (difference was not significant). The mean duration of mechanical ventilation (29.6 +/- 28.6 vs 62.3 +/- 35.7 h, respectively) and length of hospital stay (10.4 +/- 4.3 vs 15 +/- 5.2 d, respectively) among the 35 concordant surviving pairs were significantly lower in the NPV group than in the NIPPV group (p = 0.001 and p = 0.001, respectively).

CONCLUSIONS

These data suggest that both ventilatory techniques are equally effective in avoiding EI and death in COPD patients with ARF. Prospective trials are needed to confirm these preliminary results.

Для цитирования: Corrado Antonio, Confalonieri Marco, Marchese Santino, Mollica Corrado, Villella Giuseppe, Gorini Massimo, Della Porta Rossana. Iron lung vs mask ventilation in the treatment of acute on chronic respiratory failure in COPD patients: a multicenter study.. Chest. 2002. DOI: 10.1378/chest.121.1.189.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.