The feasibility and safety of substrate modification on the left atrial roof area using a cryoballoon in atrial fibrillation ablation.

Miyazaki Shinsuke, Sekihara Takayuki, Hasegawa Kanae, Mukai Moe, Aoyama Daisetsu, Nodera Minoru, Tada Hiroshi

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Data on additional substrate modification using a cryoballoon beyond cryoballoon pulmonary vein isolation (CB-PVI) is limited. We sought to evaluate the efficacy and safety of substrate modification on the left atrial roof area using CBs (LAR-CBs) for atrial fibrillation (AF) patients.

METHODS

Eighty-one AF patients (70.0[62.5-77.0] years, 33 paroxysmal AF[PAF], 48 non-PAF) underwent LAR-CBs following CB-PVIs. Voltage maps were created with a high-resolution mapping system. Roof line conduction block was evaluated during the repeat procedure.

RESULTS

The total number of applications for the CB-PVI and LAR-CB were 5.0 ± 1.2 and 3.8 ± 0.7, and both were significantly greater in non-PAF than PAF patients. LA roof areas had continuous scar in 61/79(77.2%) patients, and the mean balloon temperature was significantly lower in patients with continuous scar than those without (-39.3 ± 3.8 vs. -36.0 ± 4.6 °C, p = 0.004). The single procedure 1-year AF freedom was 87.6% (7.5% on antiarrhythmic drug) and was similar between PAF and non-PAF patients (p = 0.14). Twelve (14.8%) patients underwent a second procedure 5.5(2.2-7.5) months later, and a mean of 1.3 ± 0.5 PVs were reconnected in 7/12(58.3%) patients. Electrical conduction block across the roof line was proven in 3/12(25.0%) patients. There were 6(7.4%) complications related to the procedures, including iatrogenic roof dependent atrial tachycardia, takotsubo cardiomyopathy, and severe pericarditis in 1, 1, and 2 patients, respectively.

CONCLUSIONS

LA roof area substrate modification using CBs yielded a high arrhythmia freedom after single procedures. However, a low incidence of electrical conduction block across the line during the chronic phase and delayed complications were the major concerns.

Для цитирования: Miyazaki Shinsuke, Sekihara Takayuki, Hasegawa Kanae, Mukai Moe, Aoyama Daisetsu, Nodera Minoru, Tada Hiroshi. The feasibility and safety of substrate modification on the left atrial roof area using a cryoballoon in atrial fibrillation ablation.. International journal of cardiology. 2021. DOI: 10.1016/j.ijcard.2021.12.039.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.