MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.14237

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2021

Safety of cryoballoon ablation for the treatment of atrial fibrillation: First European results from the cryo AF Global Registry.

Földesi Csaba, Misiková Silvia, Ptaszyński Paweł, Todd Derick, Herzet Jean-Manuel, Braegelmann Kendra M, Kueffer Fred J, Drephal Christian, Steinwender Clemens, Zucchelli Giulio, Neuzil Petr, Chun Kyoung Ryul Julian

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Cryoballoon ablation for the treatment of patients with atrial fibrillation (AF) has been utilized in Europe for >15 years.

OBJECTIVES

Report patient and procedural characteristics that influence the safety of cryoablation for the treatment of AF.

METHODS

Patients enrolled in the prospective, multicenter Cryo AF Global Registry were treated at 38 European centers. Freedom from a ≥30s episode of AF/atrial flutter (AFL)/atrial tachycardia (AT) at 12-months and serious complications were analyzed. Univariate and multivariable models identified baseline patient and procedural characteristics that predicted a procedure-related complication.

RESULTS

Of the 1418 subjects who completed an index procedure, the cohort was 62 ± 11 years of age, 37.7% female, and 72.2% paroxysmal AF (PAF). The mean procedure, left atrial dwell, and fluoroscopy times were 81 ± 34, 54 ± 25, and 14 ± 13 min, respectively. Among the 766 patients with 12-month follow-up, freedom from a ≥30 s AF/AFL/AT recurrence was 83.3% (95% CI: 79.8%-86.3%) and 71.6% (95% CI: 64.6%-77.4%) in patients with PAF and persistent AF. The serious procedure- and device-related adverse event rates were 4.7% and 2.0%. No baseline patient characteristic independently predicted a procedure-related adverse event; however, prolonged procedure duration (OR = 1.01 [95% CI: 1.00-1.01]), use of general anesthesia (OR = 1.71 [95% CI: 1.01-2.92]), and delivery of a cavotricuspid isthmus line (OR = 3.04 [95% CI: 1.01-9.20]) were each independently associated with the occurrence of a serious procedural safety event (all p < .05).

CONCLUSIONS

Cryoballoon ablation is safe and effective in real-world use across a broad cohort of patients with AF.

Для цитирования: Földesi Csaba, Misiková Silvia, Ptaszyński Paweł, Todd Derick, Herzet Jean-Manuel, Braegelmann Kendra M, Kueffer Fred J, Drephal Christian, Steinwender Clemens, Zucchelli Giulio, Neuzil Petr, Chun Kyoung Ryul Julian. Safety of cryoballoon ablation for the treatment of atrial fibrillation: First European results from the cryo AF Global Registry.. Pacing and clinical electrophysiology : PACE. 2021. DOI: 10.1111/pace.14237.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.