MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1536/ihj.20-301

Медицинская библиотека · International heart journal · 2021

Quantification of Left Atrial Fibrosis in Patients After Pulmonary Vein Isolation Using the Second-Generation Cryoballoon.

Rottner Laura, Heeger Christian-Hendrik, Lemes Christine, Wohlmuth Peter, Maurer Tilman, Reissmann Bruno, Fink Thomas, Mathew Shibu, Ouyang Feifan, Kuck Karl-Heinz, Metzner Andreas, Rillig Andreas

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

Left atrial (LA) fibrosis is associated with a poor outcome after atrial fibrillation (AF) ablation. This study examined the extent of low-voltage areas in patients with recurrence of atrial tachyarrhythmia (ATA) after CB-based pulmonary vein isolation (PVI).Sixty patients (mean age 67 ± 10 years, n = 32 female; n = 34 paroxysmal AF) who received radiofrequency redo-procedure due to recurrence of ATA within 6 months after CB-based PVI were included. A point-by point 3D-map was performed, and low-voltage sites were delineated based on bipolar voltage < 0.5 mV. The extent of fibrosis was categorized as stage A (0-10% of the LA wall), stage B (10-30%), stage C (30-50%), and stage D (> 50%).The median area of LA low-voltage sites was 28.9 (9; 50.3) cm2, corresponding to 17.4 (6; 30.6) % of the LA wall surface. 17/60 (28.3%) patients were categorized as fibrosis stage A, 21/60 (35%) as stage B, 18/60 (30%) as stage C, and 4/60 (6.7%) as stage D. Patient age and LA diameter were associated with more pronounced LA fibrosis; the extent of LA fibrosis was significantly higher in patients with LA tachycardia (LAT) during redo-procedures (P < 0.01), and ablation of linear lesions was more often performed (P < 0.01).In patients after CB2-based PVI, expanded LA tissue fibrosis was associated with the occurrence of LAT and more extensive LA ablation during redo-procedures.

Для цитирования: Rottner Laura, Heeger Christian-Hendrik, Lemes Christine, Wohlmuth Peter, Maurer Tilman, Reissmann Bruno, Fink Thomas, Mathew Shibu, Ouyang Feifan, Kuck Karl-Heinz, Metzner Andreas, Rillig Andreas. Quantification of Left Atrial Fibrosis in Patients After Pulmonary Vein Isolation Using the Second-Generation Cryoballoon.. International heart journal. 2021. DOI: 10.1536/ihj.20-301.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.