MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5152/dir.2014.14217

Медицинская библиотека · Diagnostic and interventional radiology (Ankara, Turkey) · 2015

Region of interest demarcation for quantification of the apparent diffusion coefficient in breast lesions and its interobserver variability.

Nogueira Luísa, Brandão Sofia, Matos Eduarda, Nunes Rita Gouveia, Ferreira Hugo Alexandre, Loureiro Joana, Ramos Isabel

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: We aimed to compare two different methods of region of interest (ROI) demarcation and determine interobserver variability on apparent diffusion coefficient (ADC) in breast lesions.

METHODS

Thirty-two patients with 39 lesions were evaluated with a 3.0 Tesla scanner using a diffusion-weighted sequence with several b-values. Two observers independently performed the ADC measurements using: 1) a small fixed area of 10 mm2 ROI within the area with highest restriction; 2) a large ROI so as to include the whole lesion. Differences were assessed using the Wilcoxon-rank test. Bland-Altman method and Spearman coefficient were applied for interobserver variability and correlation analysis.

RESULTS

ADC values measured using the two ROI demarcation methods were significantly different for both observers (P = 0.026; P = 0.033). There was no interobserver variability in ADC values using either method (large ROI, P = 0.21; small ROI, P = 0.64). ADC values of malignant lesions were significantly different between the two methods (P < 0.001). Variability in ADC was ≤0.008×10-3 mm2/s for both methods. When using the same method, ADC values were significantly correlated between the observers (small ROI: r=0.990, P < 0.001; large ROI: r=0.985, P < 0.001).

CONCLUSION

The choice of ROI demarcation method influences ADC measurements. Small ROIs show less overlap in ADC values and higher ADC reproducibility, suggesting that this method may improve lesion discrimination. Interobserver variability was low for both methods.

Для цитирования: Nogueira Luísa, Brandão Sofia, Matos Eduarda, Nunes Rita Gouveia, Ferreira Hugo Alexandre, Loureiro Joana, Ramos Isabel. Region of interest demarcation for quantification of the apparent diffusion coefficient in breast lesions and its interobserver variability.. Diagnostic and interventional radiology (Ankara, Turkey). 2015. DOI: 10.5152/dir.2014.14217.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.