PURPOSE: The purpose of the study was to evaluate the conspicuity of bone metastases on each of the numerous sequences produced by fast Dixon-based multisequence whole-body (WB) magnetic resonance imaging (MRI) scanning in order to determine the most clinically useful sequences overall and per anatomic region.

MATERIALS AND

METHODS

Twenty-seven breast cancer patients with bone metastases were prospectively studied with fast Dixon-based WB MRI including head/neck, chest, abdominal, pelvic, thigh, calf/feet and either cervical, thoracic and lumbar or cervical/thoracic and thoracic/lumbar regions. Sequences included coronal T2, axial T1 without and with intravenous gadolinium (+C), sagittal T1 spine+C, each associated fat-only (FO) and fat-saturated (FS) sequence, axial diffusion-weighted imaging (DWI) and short tau inversion recovery (STIR). Blinded reviewers evaluated lesion conspicuity, a surrogate of clinical utility, on a five-point scale per anatomic region. Sequences were compared using analysis of variance, differences were detected with Tukey's honestly significant difference test, and the four sequences with highest mean conspicuity were compared to the remainder overall and per anatomic region.

RESULTS

Overall, a significant lesion conspicuity difference was found (P<.0001), and lesion conspicuity was significantly higher on FS T1+C, FO T1+C, T1+C sagittal and FS T1+C axial sequences (P<.0001). Per-region results were the same in the head/neck. Other sequences overlapped with these and included the following: chest/abdomen - FO T2, DWI; pelvis - DWI, FO T2; thigh - FS T2, FO T2, FO T1+C; calf/feet - FS T2, DWI, FO T2, STIR.

CONCLUSION

Overall, bone lesions were most conspicuous on FS T1+C sagittal, FO T1+C sagittal, T1+C sagittal and FS T1+C axial fast Dixon WB MRI sequences.

Для цитирования: Costelloe Colleen M, Madewell John E, Kundra Vikas, Harrell Robyn K, Bassett Roland L, Ma Jingfei. Conspicuity of bone metastases on fast Dixon-based multisequence whole-body MRI: clinical utility per sequence.. Magnetic resonance imaging. 2013. DOI: 10.1016/j.mri.2012.10.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.