MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The American journal of otology · 1998

Clinical utility of the 512-Hz Rinne tuning fork test.

Burkey J M, Lippy W H, Schuring A G, Rizer F M

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

This study aimed to examine the reliability of the 512-Hz Rinne tuning fork test to detect conductive hearing losses. The effects of tester experience, the use of masking, and the interpretation of equivocal (+/-) Rinne results on test reliability also were examined.

STUDY

DESIGN

Retrospective.

SETTING

Private otology practice.

PATIENTS: 1,000 adult patients (2,000 ears) seen for their initial otologic evaluation.

INTERVENTIONS: Diagnostic.

MAIN OUTCOME MEASURE: Sensitivity of the 512-Hz Rinne tuning fork test was assessed by comparing tuning fork results with the pure-tone average air-bone gap.

RESULTS

Results showed the 512-Hz Rinne tuning fork test could be very effective at detecting conductive hearing losses when performed by an experienced tester and when masking was used. Sensitivity was lower when masking was not used and lowest when the Rinne was performed by a less-experienced tester. Sensitivity for all groups was improved by interpreting equivocal results as indicating a conductive loss.

CONCLUSIONS

Despite reports of poor reliability, the 512-Hz Rinne tuning fork test can be an important tool in an otology practice for the detection of conductive hearing losses and for confirming audiometric findings. In primary care settings, the Rinne would be most effective as part of a screening program for conductive hearing losses, but not as the sole indicator for referral.

Для цитирования: Burkey J M, Lippy W H, Schuring A G, Rizer F M. Clinical utility of the 512-Hz Rinne tuning fork test.. The American journal of otology. 1998.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.