Unexpected Tension Pneumothorax after Double-Lumen Endotracheal Intubation in Patients with Pulmonary Edema: A Case Report.

Baek Jongyoon, Park Sang Jin, Seo Myungjin, Choi Eun Kyung

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

Tension pneumothorax is a relatively rare complication after anesthetic induction that requires prompt diagnosis and treatment. Several handling errors related to intubation procedures or equipment and vigorous positive pressure ventilation are potentially important etiologies of tension pneumothorax in patients with underlying lung disease or in mechanically ventilated patients. We describe a case of tension pneumothorax observed after double-lumen tube (DLT) insertion followed by single-lumen tube replacement using an airway exchanger catheter in a mechanically ventilated patient. An 84-year-old female on mechanical ventilation underwent minimally invasive cardiac surgery under general anesthesia. Immediately after left-sided DLT insertion using an airway exchanger catheter, oxygen saturation decreased to 89%, peak airway pressure increased to 35 cm H2O with inadequate tidal volume, and blood pressure gradually dropped to 69/41 mmHg. Breath sounds from the right hemithorax were significantly reduced. Severe collapse of the right lung, a flattened diaphragm, and compressed abdominal organs were identified on chest radiography. Therefore, a tube thoracotomy was performed based on the findings of a tension pneumothorax. Then, oxygen saturation, peak airway pressure with adequate tidal volume, and blood pressure improved, and the distended abdomen normalized. After the pneumothorax resolved, a bronchoscopy was performed. Slight redness was noted in the right bronchus, indicating that the DLT was incorrectly inserted into the right side. In conclusion, the possibility of a tension pneumothorax should be considered during DLT intubation or endotracheal tube replacement with an airway exchange catheter.

Для цитирования: Baek Jongyoon, Park Sang Jin, Seo Myungjin, Choi Eun Kyung. Unexpected Tension Pneumothorax after Double-Lumen Endotracheal Intubation in Patients with Pulmonary Edema: A Case Report.. Medicina (Kaunas, Lithuania). 2023. DOI: 10.3390/medicina59030460.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.