MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7759/cureus.66131

Медицинская библиотека · Cureus · 2024

First-in-Man Use of Intraoperative Electrophysiological Mapping to Evaluate the Efficacy of the EnCompass Clamp During a Cox-IV Maze Procedure.

Khalpey Zain, Aslam Usman, Kumar Ujjawal, Epting Leslie

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

This case report describes the first-in-man use of intraoperative electrophysiological (EP) mapping to evaluate the efficacy of the EnCompass clamp (AtriCure, Inc., Mason, OH) during a Cox-IV Maze procedure. A 53-year-old male with paroxysmal atrial fibrillation and severe mitral valve regurgitation underwent mitral valve repair with concomitant surgical ablation for atrial fibrillation. Intraoperative 3D EP mapping was performed using the Abbott EnSite Precision system (Abbott Inc., Chicago, IL) before ablation, after initial radiofrequency ablation with the AtriCure EnCompass clamp, and after the full Cox-IV Maze procedure was completed. The pre-ablation map showed approximately 80-85% high voltage areas in the posterior left atrial wall. Initial ablation with the EnCompass clamp reduced high voltage areas to 30-35%. The final map following the Cox-IV Maze procedure demonstrated near-complete electrical silence, with only 5-10% of the atrial surface retaining high voltage activity. This represents an estimated 88% reduction in high-voltage areas from baseline. The patient had an uncomplicated postoperative course apart from one episode of postoperative atrial fibrillation requiring direct current (DC) cardioversion. This case demonstrates the utility of intraoperative EP mapping in guiding and confirming the efficacy of surgical ablation procedures, as well as the effectiveness of combining the EnCompass clamp with a full Cox-IV Maze in achieving comprehensive atrial electrical isolation. The EnCompass clamp can be used for ablations with a beating heart, thus reducing the aortic cross-clamp time and therefore minimizing the total myocardial ischemia time.

Для цитирования: Khalpey Zain, Aslam Usman, Kumar Ujjawal, Epting Leslie. First-in-Man Use of Intraoperative Electrophysiological Mapping to Evaluate the Efficacy of the EnCompass Clamp During a Cox-IV Maze Procedure.. Cureus. 2024. DOI: 10.7759/cureus.66131.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.