MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00392-023-02361-7

Медицинская библиотека · Clinical research in cardiology : official journal of the German Cardiac Society · 2023

Temperature to time Catch-Up: a novel procedural endpoint to predict durable pulmonary vein isolation after cryoballoon ablation of paroxysmal atrial fibrillation.

Willy Kevin, Wolfes Julian, Müller Patrick, Ellermann Christian, Dechering Dirk, Lange Philipp S, Rath Benjamin, Reinke Florian, Doldi Florian, Güner Fatih, Köbe Julia, Leitz Patrick, Frommeyer Gerrit, Laredo Mikael, Eckardt Lars

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Cryoballoon ablation is a widely used single-shot technique for pulmonary vein isolation (PVI) in the treatment of paroxysmal atrial fibrillation (AF). Procedural endpoints ensuring maximal PVI durability are important.

OBJECTIVE

To assess the performance of cryoablation procedural markers to predict long-term PVI.

METHODS

In a single center, consecutive patients who underwent redo ablation with high-density mapping for symptomatic AF recurrence after cryoballoon ablation were included and cryoballoon procedural data were collected, including temperature values at 30 and 60 s, time to isolation, nadir temperature and the velocity of temperature decline estimated with the temperature/time catch-up point (T2T-Catch-Up) defined as positive when the freeze temperature in minus degree equals the time in seconds after cryoablation initiation (e.g. - 15 °C in the first 15 s of the ablation impulse).

RESULTS

47 patients (62% male; 58.3 ± 11.2 years) were included. Overall, 38 (80.9%) patients had ≥ 1 reconnected PV. Among 186 PVs, 56 (30.1%; 1.2 per patient on average) were reconnected. Univariate analysis revealed T2T-Catch-Up in 103 (56%) and more frequent in durably isolated than in reconnected PVs (93 [72%] vs 10 [19%], p < 0.0001). Among binary endpoints, T2T-Catch-Up had the highest specificity (82%) and predictive value for durable PVI at redo ablation (90%). In multivariable analyses, absence of T2T-Catch-Up (Odds-ratio 0.12, 95% CI [0.05-0.31], p < 0.0001) and right superior PV (Odds-ratio 3.14, 95% CI [1.27-7.74], p = 0.01) were the only variables independently associated with PV reconnection.

CONCLUSION

T2T-Catch-Up, a new and simple cryoballoon procedural endpoint demonstrated excellent predictive value and strong statistical association with durable PVI.

Для цитирования: Willy Kevin, Wolfes Julian, Müller Patrick, Ellermann Christian, Dechering Dirk, Lange Philipp S, Rath Benjamin, Reinke Florian, Doldi Florian, Güner Fatih, Köbe Julia, Leitz Patrick, Frommeyer Gerrit, Laredo Mikael, Eckardt Lars. Temperature to time Catch-Up: a novel procedural endpoint to predict durable pulmonary vein isolation after cryoballoon ablation of paroxysmal atrial fibrillation.. Clinical research in cardiology : official journal of the German Cardiac Society. 2023. DOI: 10.1007/s00392-023-02361-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.