MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5603/cj.95381

Медицинская библиотека · Cardiology journal · 2023

Right superior pulmonary vein parameter determined by three-dimensional transesophageal echocardiography is an independent predictor of the outcome after cryoballoon isolation of the pulmonary veins.

Nagy Laszlo Tibor, Papp Timea Bianka, Urbancsek Reka, Jenei Csaba, Csanadi Zoltan

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

A direct comparison of three-dimensional transesophageal echocardiography (3DTEE) and cardiac computed tomography imaging has demonstrated good inter-technique agreement for the following pulmonary vein (PV) parameters: the ostium area of the right superior PV (RSPV) and its major (a) and minor axis (b) diameters, the left lateral ridge and the minor axis (b) diameter of the left superior PV. Herein, under investigation, was the predictive value of these parameters for arrhythmia recurrence (AR) after PV isolation with the 28 mm second generation cryoballoon (CBG2).

METHODS

One hundred eleven patients (67 men, mean age 58.06 ± 10.58 years) undergoing 3DTEE before PV isolation with the CBG2 for paroxysmal atrial fibrillation were followed. "Point by point" redo intervention was offered in case of AR and reconnected PVs were defined.

RESULTS

During a mean follow-up of 617 ± 258.86 days, 65 (58.9%) patients remained free of AR. Longer RSPV b was found to be the only significant predictor for AR (hazard ratio [HR] 1.059; 95% confidence interval [CI] 1.000-1.121; p = 0.048). RSPV b ≥ 28 mm resulted in a threefold (HR 3.010; 95% CI 1.270-7.134, p = 0.012) increase in the risk of AR. The association of RSPV b with AR was independent of the biophysical parameters of cryoapplications. In 25 "redo" patients, reconnections were found 1.75 times more likely in the RSPV than in the other 3 PVs altogether.

CONCLUSIONS

Right superior PV b measured with 3DTEE might be a significant predictor of AR after PV isolation with the CBG2. In case of RSPV b exceeding 28 mm, alternative PV isolation techniques or use of a larger balloon might be considered.

Для цитирования: Nagy Laszlo Tibor, Papp Timea Bianka, Urbancsek Reka, Jenei Csaba, Csanadi Zoltan. Right superior pulmonary vein parameter determined by three-dimensional transesophageal echocardiography is an independent predictor of the outcome after cryoballoon isolation of the pulmonary veins.. Cardiology journal. 2023. DOI: 10.5603/cj.95381.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.