MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/srep33848

Медицинская библиотека · Scientific reports · 2016

Construction of a Corneal Stromal Equivalent with SMILE-Derived Lenticules and Fibrin Glue.

Yin Houfa, Qiu Peijin, Wu Fang, Zhang Wei, Teng Wenqi, Qin Zhenwei, Li Chao, Zhou Jiaojie, Fang Zhi, Tang Qiaomei, Fu Qiuli, Ma Jian, Yang Yabo

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The scarcity of corneal tissue to treat deep corneal defects and corneal perforations remains a challenge. Currently, small incision lenticule extraction (SMILE)-derived lenticules appear to be a promising alternative for the treatment of these conditions. However, the thickness and toughness of a single piece of lenticule are limited. To overcome these limitations, we constructed a corneal stromal equivalent with SMILE-derived lenticules and fibrin glue. In vitro cell culture revealed that the corneal stromal equivalent could provide a suitable scaffold for the survival and proliferation of corneal epithelial cells, which formed a continuous pluristratified epithelium with the expression of characteristic markers. Finally, anterior lamellar keratoplasty in rabbits demonstrated that the corneal stromal equivalent with decellularized lenticules and fibrin glue could repair the anterior region of the stroma, leading to re-epithelialization and recovery of both transparency and ultrastructural organization. Corneal neovascularization, graft degradation, and corneal rejection were not observed within 3 months. Taken together, the corneal stromal equivalent with SMILE-derived lenticules and fibrin glue appears to be a safe and effective alternative for the repair of damage to the anterior cornea, which may provide new avenues in the treatment of deep corneal defects or corneal perforations.

Для цитирования: Yin Houfa, Qiu Peijin, Wu Fang, Zhang Wei, Teng Wenqi, Qin Zhenwei, Li Chao, Zhou Jiaojie, Fang Zhi, Tang Qiaomei, Fu Qiuli, Ma Jian, Yang Yabo. Construction of a Corneal Stromal Equivalent with SMILE-Derived Lenticules and Fibrin Glue.. Scientific reports. 2016. DOI: 10.1038/srep33848.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.