PURPOSE: To analyze corneal stromal lamellae orientation in normal subjects and patients with various corneal conditions using a polarimetric interferometer.

METHODS

Thirty-two healthy control subjects (59 eyes) and 16 patients (22 eyes) with corneal conditions or postkeratoplasty were included in the study. All patients were imaged using the interferometer and slit lamp photography. The interferometer produces an orthogonal cross-like image of stromal lamellae by illuminating the cornea in phase-light polarization angle. Corneal haze was graded on a scale from 0 to 4. Interferometer cross-like images were graded on a scale from 0 to 5 by a masked observer. Keratometry, corneal central pachymetry, and optical densitometry were obtained with Scheimpflug corneal tomography.

RESULTS

The cross-like image was observed in 31 of 32 healthy control subjects (58 of 59 eyes) and in 13 of 16 patients (19 of 22 eyes). The image was not detectable in 3 patients, 1 with total corneal neovascularization and scarring, 1 with central leukoma, and 1 with failed deep lamellar keratoplasty. Corneal haze was the main factor obscuring the cross-like image (P < 0.05). Clarity of the images was influenced by older age, steeper keratometry, higher pachymetry, and optical density (P < 0.05). There was no correlation between the orientation of the keratometric axes and the orientation of the 2 arms of the cross-like image (P > 0.05).

CONCLUSIONS

Corneal stromal lamellae orientation can be efficiently assessed and displayed as a cross-like image by the polarimetric interferometer. Stromal lamellae orientation imaging may have potential implications in corneal diagnostics and surgery.

Для цитирования: Iovieno Alfonso, Yeung Sonia N, Nahum Yoav, Teichman Joshua, Lipari Eugenio, Busin Massimo, Fontana Luigi. Polarimetric Interferometry for Assessment of Corneal Stromal Lamellae Orientation.. Cornea. 2016. DOI: 10.1097/ico.0000000000000776.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.