DOI 10.1167/iovs.15-17098

Медицинская библиотека · Investigative ophthalmology & visual science · 2015

VesselJ: A New Tool for Semiautomatic Measurement of Corneal Neovascularization.

Rabiolo Alessandro, Bignami Fabio, Rama Paolo, Ferrari Giulio

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To quantify blood and lymph angiogenesis in mouse corneal flat mounts by means of a novel plug-in for ImageJ, called VesselJ, based on a dynamic threshold algorithm.

METHODS

Corneal neovascularization (CNV) was induced in the right corneas of 20 C57BL6/N mice by means of alkali burn (n = 10) or intrastromal sutures (n = 10). All corneal flat mounts were stained for blood vessels with CD31 and for lymphatics with LYVE1. Three independent operators measured blood and lymphatic CNV with both a published manual method (mCNV) and VesselJ (automatic method; aCNV).

RESULTS

Both methods showed a strong reliability, defined as intraclass correlation coefficient (ICC) > 0.90, in quantifying hemangiogenesis for sutures and alkali burn. However, reliability of lymphatic mCNV varied from moderate in alkali burn (ICC: 0.700) to poor in sutures (ICC: 0.415), whereas it remained high in aCNV (alkali ICC: 0.996; sutures ICC: 0.959). Among sutures, a significant correlation between mCNV and aCNV was found among all the three operators for blood vessels and just for one operator for lymphatic vessels (P < 0.001). In the alkali burn model, correlation between blood mCNV and aCNV was significant for all operators after excluding three noisy flat mounts (P < 0.001), whereas no significant correlation was seen for lymphatic vessels.

CONCLUSIONS

VesselJ is a semiautomatic, reliable, and fast method to quantify corneal hem- and lymphangiogenesis in corneal flat mounts. VesselJ can be easily used in the sutures model; it should be applied to other models (e.g., alkali burn) only after checking for background hyperfluorescence. Italian Abstract.

Для цитирования: Rabiolo Alessandro, Bignami Fabio, Rama Paolo, Ferrari Giulio. VesselJ: A New Tool for Semiautomatic Measurement of Corneal Neovascularization.. Investigative ophthalmology & visual science. 2015. DOI: 10.1167/iovs.15-17098.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.