MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1089/lrb.2012.0023

Медицинская библиотека · Lymphatic research and biology · 2013

An in vivo method for visualizing flow dynamics of cells within corneal lymphatics.

Peebo Beatrice Bourghardt, Fagerholm Per, Lagali Neil

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Monitoring the trafficking of specific cell populations within lymphatics could improve our understanding of processes such as transplant rejection and cancer metastasis. Current methods, however, lack appropriate image resolution for single-cell analysis or are incompatible with in vivo and longitudinal monitoring of lymphatics in their native state. We therefore sought to achieve high-resolution live imaging of the dynamic behavior of cells within lymph vessels in the rat cornea.

METHODS/

RESULTS

Inflammatory angiogenesis was induced by suture placement in corneas of Wistar rats. Pre- and up to 3 weeks post-induction, corneas were noninvasively examined by laser-scanning in vivo corneal confocal microscopy (IVCM) using only endogenous contrast. Lymph vessels and the cells harbored therein were documented by still images, real-time video, and 3D confocal stack reconstruction of live tissue. In vivo, conjunctival and corneal lymphatics were morphologically distinct, those with corneal location being one-quarter the diameter of those in the conjunctiva (p<0.001). Cells were recruited to initially empty pre-existing lymph vessels during the first day of inflammation and maintained a dense occupation of vessels for up to 7 days. A diverse population of cells (diameter range: 1.5-27.5 μm) with varying morphology was observed, and exhibited variable flow patterns and were transported singly and in clusters of at least 2-9 adherent cells.

CONCLUSIONS

The in vivo microscopic technique presented enables lymph vessels and cell trafficking to be studied in high resolution in a minimally-perturbed physiologic milieu.

Для цитирования: Peebo Beatrice Bourghardt, Fagerholm Per, Lagali Neil. An in vivo method for visualizing flow dynamics of cells within corneal lymphatics.. Lymphatic research and biology. 2013. DOI: 10.1089/lrb.2012.0023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.