MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ohn.162

Медицинская библиотека · Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2023

Audiometric and Patient-Reported Outcomes in Single-Sided Deafness Cochlear Implant Recipients Using the CIQOL-35.

Mitton Tanner J, Yancey Kristen L, Isaacson Brandon, Kutz Walter, Whitson Johanna, Hunter Jacob B

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Describe the effect that cochlear implantation (CI) has on audiometric outcomes and quality of life (QOL) in patients with single-sided deafness (SSD).

STUDY

DESIGN

Retrospective case review.

SETTING

Tertiary university hospital system.

METHODS

Preoperative and postoperative AzBio performance and Cochlear Implant Quality of Life-35 (CIQOL-35) Profile scores in CI patients with SSD were compared, and postoperative measures were compared to those from CI patients without SSD.

RESULTS

Seventeen patients with unilateral CI and contralateral unaided pure-tone averages ≤30 dB were included. The median age was 60.2 (interquartile range [IQR], 50.9-64.9 years), and 7/17 (41%) were women. Median daily use was 8.2 hour (IQR, 5.4-11.9 h). The median preoperative AzBio quiet score in the ear to be implanted was 3% (IQR, 0%-6%). After a median follow-up of 12.0 months, the median postoperative AzBio quiet score was 76% (IQR, 47%-86%) (p < .01). SSD subjects demonstrated statistically significant improvements in median scores on the following CIQOL-35 subdomains following implantation: Entertainment (17 preoperatively vs 21 postoperatively), Listening Effort (12 vs 14), Social (17 vs 22), and Global (28 vs 35; p < .05). SSD patients achieved equal or higher postoperative CIQOL-35 scores in most subdomains (6/7) compared to an age-matched group of non-SSD CI recipients who underwent unilaterally (N = 19) or sequential (N = 6) implantation.

CONCLUSION

SSD CI patients not only demonstrate significant improvements in speech perception testing in the implanted ear but also exhibit improvement in multiple QOL subdomains on the CIQOL-35, the only validated cochlear implant QOL instrument.

Для цитирования: Mitton Tanner J, Yancey Kristen L, Isaacson Brandon, Kutz Walter, Whitson Johanna, Hunter Jacob B. Audiometric and Patient-Reported Outcomes in Single-Sided Deafness Cochlear Implant Recipients Using the CIQOL-35.. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2023. DOI: 10.1002/ohn.162.