MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/14992027.2023.2174455

Медицинская библиотека · International journal of audiology · 2023

Acoustic reflexes: should we be paying more attention?

Prendergast Garreth, Sathe Tanvi S, Heinrich Antje, Munro Kevin J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

The clinical audiology test battery often involves playing physically simple sounds with questionable ecological value to the listener. In this technical report, we revisit how valid this approach is using an automated, involuntary auditory response; the acoustic reflex threshold (ART).

DESIGN

The ART was estimated four times in each individual in a quasi-random ordering of task conditions. The baseline condition (referred to as Neutral) measured the ART following a standard clinical practice. Three experimental conditions were then used in which a secondary task was performed whilst the reflex was measured: auditory attention, auditory distraction and visual distraction tasks.

STUDY SAMPLE: Thirty-eight participants (27 males) with a mean age of 23 years were tested. All participants were audiometrically healthy.

RESULTS

The ART was elevated when a visual task was performed at the same time as the measurements were taken. Performing an auditory task did not affect the ART.

CONCLUSIONS

These data indicate that simple audiometric measures widely used in the clinic, can be affected by central, non-auditory processes even in healthy, normal-hearing volunteers. The role of cognition and attention on auditory responses will become ever more important in the coming years.

Для цитирования: Prendergast Garreth, Sathe Tanvi S, Heinrich Antje, Munro Kevin J. Acoustic reflexes: should we be paying more attention?. International journal of audiology. 2023. DOI: 10.1080/14992027.2023.2174455.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.