MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1227/01.neu.0000362035.70735.63

Медицинская библиотека · Neurosurgery · 2010

An automated algorithm to improve the precision of basilar artery diameter measurements before and after subarachnoid hemorrhage-induced vasospasm in an animal model.

Salvetti David J, Sinha Tuhin K, Wilson Kevin J, Shay Sheila D, Spratt Daniel E, Mericle Robert A

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Quantifying vasospasm has traditionally been performed manually, a method prone to imprecision and user bias. An alternative approach is to use computerized image analysis techniques to define and quantify the diameter of a vessel. The goal of this article is to demonstrate a novel automated vessel measurement algorithm specific to the needs of vasospasm studies and to compare it with traditional manual measurements in an animal model of vasospasm.

METHODS

A total of 576 arterial diameter measurements were collected by 4 independent, blinded examiners from 24 angiograms in a rabbit subarachnoid hemorrhage (SAH) model. Measurements were taken from 3 segments of the basilar artery in anteroposterior and lateral projections, both before SAH and after SAH-induced vasospasm. Means and standard deviations of 288 manual measurements were compared with 288 automated measurements.

RESULTS

The precision of automated measurements was significantly improved compared with standardized manual measurements (85.7% decrease in variation; P < .001). When using automated measurements, the precision was not affected by vessel size, but when using manual measurements, smaller arteries were less precise (P = .04). There was no significant difference in precision between 2 different contrast concentrations (P = .32).

CONCLUSION

Automated measurements of basilar artery diameters are more precise than manual measurements, both before and after SAH-induced vasospasm. The variability in the manual group worsens when the artery is smaller secondary to vasospasm, indicating a need for the use of this segmentation method.

Для цитирования: Salvetti David J, Sinha Tuhin K, Wilson Kevin J, Shay Sheila D, Spratt Daniel E, Mericle Robert A. An automated algorithm to improve the precision of basilar artery diameter measurements before and after subarachnoid hemorrhage-induced vasospasm in an animal model.. Neurosurgery. 2010. DOI: 10.1227/01.neu.0000362035.70735.63.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.