DOI 10.1097/wno.0000000000002030
The Causes of Optic Disc Edema in Patients Presenting With Significantly Compromised Vision.
Аннотация
BACKGROUND
To evaluate the most common causes of optic disc edema (ODE) in patients with significantly compromised vision (initial best-corrected visual acuity [BCVA] of 20/400 or worse) at presentation.
METHODS
Retrospective chart review over a 5-year period of consecutive patients presenting to tertiary neuro-ophthalmology clinics at the University of Toronto.
RESULTS
A total of 656 patients with ODE were included, and 49 patients (7.47%) had an initial BCVA of 20/400 or worse. There were 54 eyes included at baseline and 49 eyes at final follow-up. There were 29 female and 20 male patients. The mean age at first visit across patients was 55.9 years. Female patients (n = 29) were significantly older than male patients (n = 20) ( P < 0.05). The causes of ODE were optic neuritis (ON) (n = 22; 40.7%), nonarteritic anterior ischemic optic neuropathy (NAION) (n = 22; 40.7%), arteritic anterior ischemic optic neuropathy (AAION) (n = 5; 9.26%), uveitis-related (n = 3; 5.56%), papilledema from idiopathic intracranial hypertension (IIH) (n = 1; 1.85%), and Vogt-Koyanagi-Harada disease (n = 1; 1.85%). Initial BCVA was not significantly different between ON and NAION groups ( P = 0.52); however, final BCVA was significantly better in the ON group ( P < 0.0001). The mean initial BCVA was worst in the AAION group (2.62 ± 0.54 logarithm of the minimum angle of resolution). The most common cause of ODE in patients <40 years old was ON (83.3%), whereas the 2 most common causes in patients >80 were NAION (60%) and AAION (40%). In patients between the ages of 60-80, NAION (100%) was the only cause.
CONCLUSIONS
Patients with ODE and poor vision at presentation represent a minority of cases seen in neuro-ophthalmology clinics (<10%). Optic neuritis and NAION are the 2 most common causes of ODE with poor vision at presentation. These findings are limited by a small sample size and potential sampling bias.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.