MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1212/nxi.0000000000200169

Медицинская библиотека · Neurology(R) neuroimmunology & neuroinflammation · 2023

The OSCAR-MP Consensus Criteria for Quality Assessment of Retinal Optical Coherence Tomography Angiography.

Wicklein Rebecca, Yam Charmaine, Noll Christina, Aly Lilian, Banze Nicolas, Romahn Eva Feodora, Wolf Elisabeth, Hemmer Bernhard, Oertel Frederike C, Zimmermann Hanna, Albrecht Philipp, Ringelstein Marius, Baumann Carmen, Feucht Nikolaus, Penkava Josef, Havla Joachim, Gernert Jonathan A, Mardin Christian, Vasileiou Eleni S, Van Der Walt Anneke, Al-Louzi Omar, Cabello Sergio, Vidal-Jordana Angela, Krämer Julia, Wiendl Heinz, Preiningerova Jana Lizrova, Ciccarelli Olga, Garcia-Martin Elena, Kana Veronika, Calabresi Peter A, Paul Friedemann, Saidha Shiv, Petzold Axel, Toosy Ahmed T, Knier Benjamin, IMSVISUAL Consortium

СтатьяОбзорПоддержка исследования: вне правительства СШАConsensus StatementПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVES

Optical coherence tomography angiography (OCTA) is a noninvasive high-resolution imaging technique for assessing the retinal vasculature and is increasingly used in various ophthalmologic, neuro-ophthalmologic, and neurologic diseases. To date, there are no validated consensus criteria for quality control (QC) of OCTA. Our study aimed to develop criteria for OCTA quality assessment.

METHODS

To establish criteria through (1) extensive literature review on OCTA artifacts and image quality to generate standardized and easy-to-apply OCTA QC criteria, (2) application of OCTA QC criteria to evaluate interrater agreement, (3) identification of reasons for interrater disagreement, revision of OCTA QC criteria, development of OCTA QC scoring guide and training set, and (4) validation of QC criteria in an international, interdisciplinary multicenter study.

RESULTS

We identified 7 major aspects that affect OCTA quality: (O) obvious problems, (S) signal strength, (C) centration, (A) algorithm failure, (R) retinal pathology, (M) motion artifacts, and (P) projection artifacts. Seven independent raters applied the OSCAR-MP criteria to a set of 40 OCTA scans from people with MS, Sjogren syndrome, and uveitis and healthy individuals. The interrater kappa was substantial (κ 0.67). Projection artifacts were the main reason for interrater disagreement. Because artifacts can affect only parts of OCTA images, we agreed that prior definition of a specific region of interest (ROI) is crucial for subsequent OCTA quality assessment. To enhance artifact recognition and interrater agreement on reduced image quality, we designed a scoring guide and OCTA training set. Using these educational tools, 23 raters from 14 different centers reached an almost perfect agreement (κ 0.92) for the rejection of poor-quality OCTA images using the OSCAR-MP criteria.

DISCUSSION: We propose a 3-step approach for standardized quality control: (1) To define a specific ROI, (2) to assess the occurrence of OCTA artifacts according to the OSCAR-MP criteria, and (3) to evaluate OCTA quality based on the occurrence of different artifacts within the ROI. OSCAR-MP OCTA QC criteria achieved high interrater agreement in an international multicenter study and is a promising QC protocol for application in the context of future clinical trials and studies.

Для цитирования: Wicklein Rebecca, Yam Charmaine, Noll Christina, Aly Lilian, Banze Nicolas, Romahn Eva Feodora, Wolf Elisabeth, Hemmer Bernhard, Oertel Frederike C, Zimmermann Hanna, Albrecht Philipp, Ringelstein Marius, Baumann Carmen, Feucht Nikolaus, Penkava Josef, Havla Joachim, Gernert Jonathan A, Mardin Christian, Vasileiou Eleni S, Van Der Walt Anneke, Al-Louzi Omar, Cabello Sergio, Vidal-Jordana Angela, Krämer Julia, Wiendl Heinz, Preiningerova Jana Lizrova, Ciccarelli Olga, Garcia-Martin Elena, Kana Veronika, Calabresi Peter A, Paul Friedemann, Saidha Shiv, Petzold Axel, Toosy Ahmed T, Knier Benjamin, IMSVISUAL Consortium. The OSCAR-MP Consensus Criteria for Quality Assessment of Retinal Optical Coherence Tomography Angiography.. Neurology(R) neuroimmunology & neuroinflammation. 2023. DOI: 10.1212/nxi.0000000000200169.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.