DOI 10.1016/j.wneu.2020.12.177
Stroke Microsurgical Thrombectomy Human Placenta Simulator.
Аннотация
BACKGROUND
Stroke microsurgical cerebrovascular thrombectomy reports are limited, although this technique could be used in many centers as a primary treatment or a salvage intervention option. It requires great ability, so our aim is to describe and validate a stroke microsurgical thrombectomy ex vivo simulator with operative nuances analysis.
METHODS
Human placenta (HP) models simulated middle cerebral artery vessels with intraluminal thrombus to be microsurgically excised. Six neurosurgeons performed 1-mm and 2-mm longitudinal and transverse arteriotomy in different arteries to remove a 1.5-cm length thrombus. Validation through construct validity compared time to complete the task, complete vessel cleaning, vessel manipulation, vessel stenosis, and leakage in both techniques.
RESULTS
All 6 HP models reproduced with fidelity stroke microsurgical thrombectomy, so participants completed 24 sessions, 4 for each neurosurgeon on the same model in different arteries. Construct validity highlighted microsurgical technical difficulties with positive results obtained by parameters variation during performance. Transverse arteriotomy with 1-mm length had best results (P < 0.05) allowing complete thrombus removal, less stenosis, and minor leakage in abbreviated time.
CONCLUSIONS
A HP simulator can reproduce with high fidelity all stroke microsurgical thrombectomy part tasks. Transverse 1-mm arteriotomy followed by thrombectomy and 2 simple sutures can fulfill all quality assurance aspects in such intervention accordingly to training model, due to easier vessel opening, complete thrombus removal, no stenosis, and faster microsuture.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.