Transorbital ultrasonography for measuring optic nerve atrophy in multiple sclerosis.
Аннотация
OBJECTIVE
we aimed to evaluate the utility of transorbital ultrasonography (TOS) in optic nerve assessment and quantification of ON atrophy in MS patients, and to determine whether ON atrophy correlates with the disease duration and disability measured on the Kurtzke Expanded Disability Status Scale (EDSS).
MATERIALS AND
METHODS
Prospective, multicentre, blinded cohort study of 59 patients diagnosed with relapsing-remitting MS and 36 controls.
RESULTS
When measured with TOS, the diameter of both the right (2.69 ± 0.30 mm in cases; 3.20 ± 0.19 mm in controls, P < .0001) and left (2.71 ± 0.26 mm in cases; 3.24 ± 0.15 mm controls, P < .0001) ON of study patients was smaller than controls. We observed a negative correlation between EDSS and both right (ρ = .524) and left (ρ = .469) ON diameter. We also observed a negative correlation between disease duration and both right (r = .602) and left (r = .538) ON diameter. No difference was observed in the diameter of both ON among patients with a history of optic neuritis (right OND 2.68 ± 0.29 mm; left OND 2.69 ± 0.25 mm) and patients with no history of optic neuritis (right OND 2.70 ± 0.30 mm; left OND 2.73 ± 0.27 mm) (P = .805; P = .651).
CONCLUSIONS
The thickness of ON measured with TOS is correlated with EDSS and the duration of the disease without being interfered by the previous history of optic neuritis. TOS could be a reliable technique for measuring ON atrophy in MS.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.