Optic Nerve Head Blood Flow, as Measured by Laser Speckle Flowgraphy, Is Significantly Reduced in Preperimetric Glaucoma.

Shiga Yukihiro, Kunikata Hiroshi, Aizawa Naoko, Kiyota Naoki, Maiya Yukiko, Yokoyama Yu, Omodaka Kazuko, Takahashi Hidetoshi, Yasui Tomoki, Kato Keiichi, Iwase Aiko, Nakazawa Toru

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To compare optic nerve head (ONH) blood flow in healthy eyes, eyes with preperimetric glaucoma (PPG), and eyes with mild normal-tension glaucoma (NTG) using laser speckle flowgraphy (LSFG).

METHODS

In 172 eyes (normal: 44 eyes; PPG: 62 eyes; mild NTG: 66 eyes), LSFG was used to measure mean blur rate in the ONH tissue area (MBRT), an index of capillary blood flow. Multiple regression analysis was performed to determine factors affecting circumpapillary retinal nerve fiber layer thickness (cpRNFLT), mean deviation (MD) and pattern standard deviation (PSD) of the visual field.

RESULTS

Despite similar characteristics in age, refractive error and systemic variables among the study groups, MBRT in the normal eyes differed significantly from both the PPG and mild NTG eyes (P = 0.001, P < 0.001, respectively). Multiple regression analysis revealed that MBRT was an independent factor affecting cpRNFLT, MD and PSD (P < 0.001, P = 0.001, P = 0.003, respectively).

CONCLUSION

ONH blood flow was detectibly reduced in eyes with PPG, in close association with structural and visual field damage. This suggests that measuring ONH tissue-area blood flow with LSFG may be a useful way of monitoring glaucoma severity, even in the early stages of glaucoma.

Для цитирования: Shiga Yukihiro, Kunikata Hiroshi, Aizawa Naoko, Kiyota Naoki, Maiya Yukiko, Yokoyama Yu, Omodaka Kazuko, Takahashi Hidetoshi, Yasui Tomoki, Kato Keiichi, Iwase Aiko, Nakazawa Toru. Optic Nerve Head Blood Flow, as Measured by Laser Speckle Flowgraphy, Is Significantly Reduced in Preperimetric Glaucoma.. Current eye research. 2016. DOI: 10.3109/02713683.2015.1127974.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.