MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/tbme.2006.873396

Медицинская библиотека · IEEE transactions on bio-medical engineering · 2006

Classification of unilateral vocal fold paralysis by endoscopic digital high-speed recordings and inversion of a biomechanical model.

Schwarz Raphael, Hoppe Ulrich, Schuster Maria, Wurzbacher Tobias, Eysholdt Ulrich, Lohscheller Jörg

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод пока не подготовлен

Аннотация

Hoarseness in unilateral vocal fold paralysis is mainly due to irregular vocal fold vibrations caused by asymmetries within the larynx physiology. By means of a digital high-speed camera vocal fold oscillations can be observed in real-time. It is possible to extract the irregular vocal fold oscillations from the high-speed recordings using appropriate image processing techniques. An inversion procedure is developed which adjusts the parameters of a biomechanical model of the vocal folds to reproduce the irregular vocal fold oscillations. Within the inversion procedure a first parameter approximation is achieved through a knowledge-based algorithm. The final parameter optimization is performed using a genetic algorithm. The performance of the inversion procedure is evaluated using 430 synthetically generated data sets. The evaluation results comprise an error estimation of the inversion procedure and show the reliability of the algorithm. The inversion procedure is applied to 15 healthy voice subjects and 15 subjects suffering from unilateral vocal fold paralysis. The optimized parameter sets allow a classification of pathologic and healthy vocal fold oscillations. The classification may serve as a basis for therapy selection and quantification of therapy outcome in case of unilateral vocal fold paralysis.

Для цитирования: Schwarz Raphael, Hoppe Ulrich, Schuster Maria, Wurzbacher Tobias, Eysholdt Ulrich, Lohscheller Jörg. Classification of unilateral vocal fold paralysis by endoscopic digital high-speed recordings and inversion of a biomechanical model.. IEEE transactions on bio-medical engineering. 2006. DOI: 10.1109/tbme.2006.873396.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.