DOI 10.1016/j.jcrs.2012.10.040
Early postoperative safety and surgical outcomes after implantation of a suprachoroidal micro-stent for the treatment of open-angle glaucoma concomitant with cataract surgery.
Аннотация
PURPOSE: To evaluate the safety of a new suprachoroidal device, the Cypass micro-stent, for the surgical treatment of open-angle glaucoma (OAG) implanted in conjunction with cataract surgery.
SETTING
Multicenter clinical study.
DESIGN
Prospective interventional case series.
METHODS
This is an interim report of an ongoing safety study. Patients with OAG glaucoma (Shaffer grade 3 and 4) who were also candidates for cataract surgery in the affected eye had standard phacoemulsification followed by micro-stent implantation in the supraciliary space. Included were patients with uncontrolled (≥ 21 mm Hg, Cohort 1) or controlled (<21 mm Hg, Cohort 2) medicated intraocular pressure (IOP) at baseline. Glaucoma medications were discontinued at surgery and resumed at the discretion of each investigator. Measures included adverse events/complications and postoperative changes in IOP or medication.
RESULTS
The mean baseline medicated IOP was 21.1 mm Hg ± 5.91 (SD); the mean number of IOP-lowering medications was 2.1 ± 1.1 (N = 184). There were no major events such as retinal or choroidal detachment or endophthalmitis. The most common complications were transient early hypotony (13.8%) and transient IOP increase (10.5%). Uncontrolled patients (n = 57) had a 37% IOP reduction (P<.001), with more than a 50% reduction in glaucoma medications at 6 months (P<.001). Intraocular pressure-controlled patients (n = 41) had a 71.4% reduction in glaucoma medications (P<.001).
CONCLUSION
Initial clinical experience with the new micro-stent showed a low rate of surgical complications with concomitant decreases in IOP and/or glaucoma medications.