MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-2007-962957

Медицинская библиотека · Klinische Monatsblatter fur Augenheilkunde · 2007

Pars plana vitrectomy with 25-gauge instruments in the treatment of idiopathic epiretinal membranes.

Valmaggia C

Контролируемое клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The sutureless pars plana vitrectomy (ppv) using a 25-gauge instrumentation is a minimally invasive technique which is mainly performed for procedures that do not require extensive vitreous dissection. In a consecutive case series with retrospective collection of data, the advantages and the risks of this technique are discussed in comparison with the conventional 20-gauge ppv for patients with idiopathic epiretinal membranes.

PATIENTS AND

METHODS

Between July 2003 and November 2004, 64 consecutive patients (26 men, 38 women, mean age: 72 years) were treated with a 20-gauge ppv, and between December 2004 and January 2006, 75 consecutive patients (42 men, 33 women, mean age: 70.4 years) were treated with a 25-gauge ppv. The patients were classified into three groups: ppv combined with phacoemulsification (group 1), ppv in pseudophakic eyes (group 2), or ppv without phacoemulsification (group 3). There were postoperative controls after at least 1, 30 and 180 days.

RESULTS

The visual acuity improves quicker in the groups 1 and 2 of the 25-gauge ppv compared with the 20-gauge ppv due to less postoperative inflammation and to the practical absence of postoperative astigmatism. In the group 3, after using either a 25-gauge or a 20 gauge ppv, the development of a postoperative cataract restrained the improvement of the visual acuity. The following postoperative complications were noticed using the 25-gauge ppv: transitory hypotonia with an eye pressure < 5 mmHg (9 cases) and with attendant choroidal detachment (3 cases), macular oedema (1 case), and endophthalmitis (1 case); using the 20-gauge ppv: transitory hypertonia (9 cases), macular oedema (2 cases), and retinal detachment (3 cases).

CONCLUSIONS

The sutureless 25-gauge ppv is advantageous for a quick postoperative recovery of the visual acuity, and may be well combined with cataract surgery. Nevertheless, this technique involves risks and its further evaluation, especially in comparison using a 23-gauge ppv, is indicated.

Для цитирования: Valmaggia C. Pars plana vitrectomy with 25-gauge instruments in the treatment of idiopathic epiretinal membranes.. Klinische Monatsblatter fur Augenheilkunde. 2007. DOI: 10.1055/s-2007-962957.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.