Interobserver Agreement in the Diagnosis of Parkinson Disease with Cardiac 123I-Metaiodobenzylguanidine Scintigraphy.
Аннотация
The aim of this study was to analyze the interobserver agreement of visual and quantitative assessment of cardiac 123I-metaiodobenzylguanidine scintigraphy.
Methods
Planar images were acquired using a low-energy collimator. The heart-to-mediastinum (HM) ratio was adjusted for the use of a low-energy collimator, using a published formula. Interpretation was undertaken both visually and after the addition of adjusted HM ratios. Image findings were classified as normal, abnormal, or borderline.
Results
The cohort consisted of 10 patients. On visual interpretation only, there was strong agreement on the interpretation of the scan (κ = 0.82, P < 0.01). Adjusted HM ratios led to a significant increase in mean ratios (1.79 vs. 1.36, P = 0.02) and, when utilized in reporting, resulted in perfect agreement (κ = 1.0, P < 0.01).
Conclusion
The use of quantified HM ratios adjusted for low-energy collimator use improves on visual assessment alone and allowed for excellent interobserver agreement.