Development of an audiological assessment and diagnostic model for high occupational noise exposure.

Yuan Hao, Ma Peng-Wei, Chen Jia-Wei, Wang Wei-Long, Gao Wei, Lu Pei-Heng, Ding Xue-Rui, Lun Yu-Qiang, Lu Lian-Jun

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To explore the diagnostic auditory indicators of high noise exposure and combine them into a diagnostic model of high noise exposure and possible development of hidden hearing loss (HHL).

METHODS

We recruited 101 young adult subjects and divided them according to noise exposure history into high-risk and low-risk groups. All subjects completed demographic characteristic collection (including age, noise exposure, self-reported hearing status, and headset use) and related hearing examination.

RESULTS

The 8 kHz (P = 0.039) and 10 kHz (P = 0.005) distortion product otoacoustic emission amplitudes (DPOAE) (DPs) in the high-risk group were lower than those in the low-risk group. The amplitudes of the summating potential (SP) (P = 0.017) and action potential (AP) (P = 0.012) of the electrocochleography (ECochG) in the high-risk group were smaller than those in the low-risk group. The auditory brainstem response (ABR) wave III amplitude in the high-risk group was higher than that in the low-risk group. When SNR = - 7.5 dB (P = 0.030) and - 5 dB (P = 0.000), the high-risk group had a lower speech discrimination score than that of the low-risk group. The 10 kHz DPOAE DP, ABR wave III amplitude and speech discrimination score under noise with SNR = - 5 dB were combined to construct a combination diagnostic indicator. The area under the ROC curve was 0.804 (95% CI 0.713-0.876), the sensitivity was 80.39%, and the specificity was 68.00%.

CONCLUSIONS

We expect that high noise exposure can be detected early with this combined diagnostic indicator to prevent HHL or sensorineural hearing loss (SNHL).

TRIAL REGISTRATION NUMBER/DATE OF REGISTRATION: ChiCTR2200057989, 2022/3/25.

Для цитирования: Yuan Hao, Ma Peng-Wei, Chen Jia-Wei, Wang Wei-Long, Gao Wei, Lu Pei-Heng, Ding Xue-Rui, Lun Yu-Qiang, Lu Lian-Jun. Development of an audiological assessment and diagnostic model for high occupational noise exposure.. European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery. 2022. DOI: 10.1007/s00405-022-07787-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.