MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/ceo.12271

Медицинская библиотека · Clinical & experimental ophthalmology · 2013

Thin lenticule Descemet's stripping automated endothelial keratoplasty: single, slow pass technique.

Vajpayee Rasik B, Maharana Prafulla K, Jain Shreyans, Sharma Namrata, Jhanji Vishal

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

To evaluate the outcomes of single pass thin lenticule sutureless Descemet's stripping automated endothelial keratoplasty with donor lenticules prepared using a 400 μm microkeratome head.

DESIGN

Interventional case series.

PARTICIPANTS

Cases with corneal endothelial dysfunction.

METHODS

Fifteen cases with corneal endothelial dysfunction (eight pseudophakic bullous keratopathy, three Fuchs' endothelial dystrophy, three congenital hereditary endothelial dystrophy and one failed graft) underwent thin lenticule Descemet's stripping automated endothelial keratoplasty at a tertiary care hospital. Donor lenticule was prepared with a single pass 400 μm Carriazo Barraquer microkeratome (Moria, Antony, France) head. Sutureless Descemet's stripping automated endothelial keratoplasty was performed in all the cases through a 3.5 mm corneoscleral tunnel using a Busin glide for graft insertion.

MAIN OUTCOME MEASURES: Main parameters evaluated were postoperative donor lenticule thickness and best-corrected visual acuity.

RESULTS

Donor lenticules were harvested successfully for all 15 cases without any complications. At 6-months follow up, the mean logMAR best-corrected visual acuity improved from 1.87 ± 0.52 to 0.109 ± 0.11 (P = < 0.0001). The mean donor lenticule thickness was 111 ± 17.62 μm (range 70-134 μm) at the last follow up. The mean endothelial cell loss was 26.33 ± 1.34%.

CONCLUSIONS AND RELEVANCE: Thin donor lenticules for Descemet's stripping automated endothelial keratoplasty can be safely harvested using a single pass technique with 400 μm microkeratome head and can be used for a successful Descemet's stripping automated endothelial keratoplasty surgery.

Для цитирования: Vajpayee Rasik B, Maharana Prafulla K, Jain Shreyans, Sharma Namrata, Jhanji Vishal. Thin lenticule Descemet's stripping automated endothelial keratoplasty: single, slow pass technique.. Clinical & experimental ophthalmology. 2013. DOI: 10.1111/ceo.12271.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.