OBJECTIVE

To evaluate Descemet membrane endothelial keratoplasty for management of corneal endothelial disorders.

METHODS

Descemet membrane endothelial keratoplasty was performed in 200 patients with Fuchs endothelial dystrophy or bullous keratopathy. Best-corrected visual acuity, subjective and objective refractive outcome and stability, and endothelial cell density were evaluated at 1, 3, and 6 months postoperatively, and intraoperative and postoperative complications were documented.

RESULTS

At 6 months, 94% reached a best-corrected visual acuity of 20/40 or better (≥0.5); 77%, 20/25 or better (≥0.8); 47%, 20/20 or better (≥1.0), and 16%, 20/17 or better (≥1.2) (n = 159). The preoperative to 6 months' postoperative spherical equivalent showed a mean (SD) +0.38 (1.2) diopter hyperopic shift (P = .001) that correlated with a decrease in central corneal thickness (n = 143) (P = .047). Two-thirds of eyes showed refractive stability at 3 months. Donor endothelial cell density showed a decrease from mean (SD) 2560 (186) cells/mm(2) preoperatively to 1690 (520) cells/mm(2) at 6 months after surgery (n = 173) (P < .001). Graft detachment was the main complication and occurred in 18 eyes (9%). Recipient Descemet membrane remnants were present in 12 eyes (6%). Secondary glaucoma was seen in 8 eyes (4%), of which 4 showed air-bubble dislocation behind the iris. In 2 of 33 phakic eyes (6%), a secondary cataract developed requiring phacoemulsification.

CONCLUSIONS

Descemet membrane endothelial keratoplasty may offer complete visual rehabilitation within 1 to 6 months after surgery in a majority of eyes. Similar to earlier keratoplasty techniques, Descemet membrane endothelial keratoplasty may be associated with a one-third decrease in donor endothelial cell density in the early postoperative phase. Incidence of (partial) graft detachment stabilized at about 5% but could be further reduced by patient selection and/or technique modification.

TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00521898.

Для цитирования: Dirisamer Martin, Ham Lisanne, Dapena Isabel, Moutsouris Kyros, Droutsas Konstantinos, van Dijk Korine, Frank Laurence E, Oellerich Silke, Melles Gerrit R J. Efficacy of descemet membrane endothelial keratoplasty: clinical outcome of 200 consecutive cases after a learning curve of 25 cases.. Archives of ophthalmology (Chicago, Ill. : 1960). 2011. DOI: 10.1001/archophthalmol.2011.195.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.