DOI 10.1016/j.jvscit.2025.102041
A nonstandard custom-made device to treat a type IA endoleak 6 years after Nellix implantation.
Аннотация
The Nellix graft has been withdrawn from the market for the early graft failures associated with sac enlargement and rupture. To manage this complication, open conversion has been described as the main solution. However, we report the case of an 85-year-old female patient admitted with a type IA endoleak on a Nellix graft, with 70-mm aneurysmal sac, and treated with a custom-made device manufactured by Cook, to fit the peculiar graft conformation and patient's anatomy. In this case, accurate prosthesis design and surgical planning were essential to complete the procedure with no intraoperative complications.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.