MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvssci.2025.100284

Медицинская библиотека · JVS-vascular science · 2025

Contrast-enhanced ultrasound microbubble uptake and abnormal plasma biomarkers are seen in patients with abdominal aortic aneurysms.

Abou Ali Adham N, Cherfan Patrick, Taha Ashraf G, Makaroun Michel S, Zhang Yingze, Chen Xucai X, Villanueva Flordeliza S, Chaer Rabih A

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Abdominal aortic aneurysm (AAA) growth is unpredictable. We hypothesize that contrast-enhanced ultrasound (CEUS) imaging and plasma inflammatory biomarkers (PIBs) may detect AAA wall inflammation.

METHODS

Patients with an AAA diameter ≥4 cm had CEUS and PIB testing at enrollment and every 6 months. Microbubble replenishment was analyzed via manually drawn regions of the aortic wall. Aneurysm growth, rupture, and repair were recorded. PIB testing was analyzed using biomarker panels. Independent and paired t-tests were used to detect differences in PIB levels. Logistic regression was used to study the association between PIBs, microbubble uptake, and AAA growth.

RESULTS

A total of 59 patients were enrolled (mean age, 68.8 ± 8.6 years; 13.6% female; 93.2% White). Mean AAA size on presentation was 41.6 ± 6.7 mm. Microbubble uptake was seen in 36 patients (61%). Patients with AAA had high baseline levels of Cystatin C and interferon-γ and low levels of macrophage migration inhibitory factor. Microbubble uptake was seen in 59% of patients with ≥5 mm AAA growth but was not predictive of growth on logistic regression.

CONCLUSIONS

We have demonstrated that microbubble uptake with CEUS is seen in the aortic wall/intraluminal thrombus of patients with AAA. CEUS and PIBs could provide insight into aneurysm behavior in newly diagnosed AAA.

Для цитирования: Abou Ali Adham N, Cherfan Patrick, Taha Ashraf G, Makaroun Michel S, Zhang Yingze, Chen Xucai X, Villanueva Flordeliza S, Chaer Rabih A. Contrast-enhanced ultrasound microbubble uptake and abnormal plasma biomarkers are seen in patients with abdominal aortic aneurysms.. JVS-vascular science. 2025. DOI: 10.1016/j.jvssci.2025.100284.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.