MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fcvm.2025.1629547

Медицинская библиотека · Frontiers in cardiovascular medicine · 2025

Case Report: preoperative prediction of aneurysm rupture site using aortic morphological and biomechanical analysis validated by intraoperative imaging.

Huang Tianming, Pan Yifeng, Lin Shuangxiang, Luo Yuanming, Chen Bing

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

Prediction of aneurysm rupture has been a great challenge for decades. We report a successful rupture site prediction on a 97 mm abdominal aortic aneurysm (AAA). A 73-year-old man with an 11-year history of AAA presented to our outpatient clinic with a one-week history of hemoptysis. After undergoing multidimensional dynamic CTA imaging, the high rupture risk region was predicted through comprehensively inspecting the image-derived characteristics of biomechanics, morphology, and intraluminal thrombus distribution. Owing to financial difficulties, the patient declined treatment. The patient returned to the hospital 140 days later with severe acute abdominal pain. Follow-up CT imaging revealed contrast extravasation accompanied by a large retroperitoneal hematoma, indicating active aneurysmal rupture. Emergency endovascular aneurysm repair (EVAR) was subsequently performed. Notably, the rupture site corresponded to the region previously predicted by our biomechanical analysis and was confirmed intraoperatively via digital subtraction angiography. The patient's postoperative course was uneventful, and he remained in stable condition at the 3-month follow-up. This successful prediction serves as a starting point for verifying the considerations regarding aneurysm rupture mechanism, which would benefits innovative treatment options in future.

Для цитирования: Huang Tianming, Pan Yifeng, Lin Shuangxiang, Luo Yuanming, Chen Bing. Case Report: preoperative prediction of aneurysm rupture site using aortic morphological and biomechanical analysis validated by intraoperative imaging.. Frontiers in cardiovascular medicine. 2025. DOI: 10.3389/fcvm.2025.1629547.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.