MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/14992027.2020.1832266

Медицинская библиотека · International journal of audiology · 2020

Sound therapy for cochlear implant users with tinnitus.

van Heteren Jan A A, Arts Remo A G J, Killian Matthijs J P, Assouly Kelly K S, van de Wauw Cynthia, Stokroos Robert J, Smit Adriana L, George Erwin L J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

Despite the positive effect of a cochlear implant (CI) on tinnitus in many patients, tinnitus remains a problem for a significant proportion of CI users. We investigated the acceptability and effect of sound therapy (a combination of natural background sounds and one concise tinnitus counselling session) on tinnitus and speech perception in CI users who still experienced tinnitus during CI use.

DESIGN AND STUDY SAMPLE: Thirty-two CI users (32-78 years) participated in phase 1: a test at the clinic to evaluate six background sounds provided by the sound processor. Eighteen out of the 32 CI users participated in phase 2: an optional take-home evaluation of 2 weeks without sound therapy, followed by 5 weeks with sound therapy, ending with an evaluation visit.

RESULTS

Thirty subjects (93.8%) found at least one background sound acceptable. In phase 2, a small improvement with sound therapy was found for tinnitus loudness, annoyance, and intrusiveness. 50% of the subjects subjectively reported benefit of sound therapy. Especially the sense of control on their tinnitus was highly appreciated. No detrimental effect on speech perception was observed.

CONCLUSION

The background sounds were acceptable and provided tinnitus relief in some CI users with tinnitus during CI use.

Для цитирования: van Heteren Jan A A, Arts Remo A G J, Killian Matthijs J P, Assouly Kelly K S, van de Wauw Cynthia, Stokroos Robert J, Smit Adriana L, George Erwin L J. Sound therapy for cochlear implant users with tinnitus.. International journal of audiology. 2020. DOI: 10.1080/14992027.2020.1832266.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.