MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejcts.2007.04.035

Медицинская библиотека · European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2007

Totally normothermic aortic arch replacement without circulatory arrest.

Touati Gilles D, Marticho Paul, Farag Moataz, Carmi Doron, Szymanski Catherine, Barry Misbaou, Trojette Faouzi, Caus Thierry

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Various techniques have been proposed for cerebral protection during the surgical treatment of complex aortic disease. The authors propose a revisited strategy of normothermic replacement of the aortic arch to avoid limitations and complications of profound hypothermic circulatory arrest.

MATERIALS AND

METHODS

From April 2000 to May 2006, 19 patients with an aneurysm of the aortic arch and 10 patients with an acute (7) or a chronic (3) aortic dissection underwent a totally normothermic, complete replacement of the aortic arch using three pumps: One pump ensured antegrade cerebral perfusion, at a flow rate adapted to obtain a pressure of 70 mmHg in the right radial artery, and required a selective cannulation of the supra-aortic vessels. A second pump ensured body perfusion at a flow rate adapted to obtain a pressure of 55 mmHg in the left femoral artery and was situated between the right femoral artery and the right atrium. A special balloon aortic occlusion catheter was placed in the descending thoracic aorta. A third pump ensured intermittent normothermic myocardial perfusion via the coronary venous sinus. The arch reconstruction was performed with no time limit.

RESULTS

There were two operative, in-hospital (6.8%) mortalities. All others patients were rapidly extubated, except one, with no neurological sequelae, and postoperative course was uneventful, without coagulopathy or hepato-renal impairment.

CONCLUSIONS

In the light of these results, a normothermic procedure is possible for arch surgery and may ensure a more physiological autoregulation of cerebral blood flow while maintaining body perfusion without high vascular resistances.

Для цитирования: Touati Gilles D, Marticho Paul, Farag Moataz, Carmi Doron, Szymanski Catherine, Barry Misbaou, Trojette Faouzi, Caus Thierry. Totally normothermic aortic arch replacement without circulatory arrest.. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 2007. DOI: 10.1016/j.ejcts.2007.04.035.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.