MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0303846

Медицинская библиотека · PloS one · 2024

Prospective multicentre accuracy evaluation of the FUJIFILM SILVAMP TB LAM test for the diagnosis of tuberculosis in people living with HIV demonstrates lot-to-lot variability.

Székely Rita, Sossen Bianca, Mukoka Madalo, Muyoyeta Monde, Nakabugo Elizabeth, Hella Jerry, Nguyen Hung Van, Ubolyam Sasiwimol, Chikamatsu Kinuyo, Macé Aurélien, Vermeulen Marcia, Centner Chad M, Nyangu Sarah, Sanjase Nsala, Sasamalo Mohamed, Dinh Huong Thi, Ngo The Anh, Manosuthi Weerawat, Jirajariyavej Supunnee, Mitarai Satoshi, Nguyen Nhung Viet, Avihingsanon Anchalee, Reither Klaus, Nakiyingi Lydia, Kerkhoff Andrew D, MacPherson Peter, Meintjes Graeme, Denkinger Claudia M, Ruhwald Morten, FujiLAM Study Consortium

СтатьяМногоцентровое исследованиеКлиническое исследованиеПеревод в очереди

Аннотация

There is an urgent need for rapid, non-sputum point-of-care diagnostics to detect tuberculosis. This prospective trial in seven high tuberculosis burden countries evaluated the diagnostic accuracy of the point-of-care urine-based lipoarabinomannan assay FUJIFILM SILVAMP TB LAM (FujiLAM) among inpatients and outpatients living with HIV. Diagnostic performance of FujiLAM was assessed against a mycobacterial reference standard (sputum culture, blood culture, and Xpert Ultra from urine and sputum at enrollment, and additional sputum culture ≤7 days from enrollment), an extended mycobacterial reference standard (eMRS), and a composite reference standard including clinical evaluation. Of 1637 participants considered for the analysis, 296 (18%) were tuberculosis positive by eMRS. Median age was 40 years, median CD4 cell count was 369 cells/ul, and 52% were female. Overall FujiLAM sensitivity was 54·4% (95% CI: 48·7-60·0), overall specificity was 85·2% (83·2-87·0) against eMRS. Sensitivity and specificity estimates varied between sites, ranging from 26·5% (95% CI: 17·4%-38·0%) to 73·2% (60·4%-83·0%), and 75·0 (65·0%-82·9%) to 96·5 (92·1%-98·5%), respectively. Post-hoc exploratory analysis identified significant variability in the performance of the six FujiLAM lots used in this study. Lot variability limited interpretation of FujiLAM test performance. Although results with the current version of FujiLAM are too variable for clinical decision-making, the lipoarabinomannan biomarker still holds promise for tuberculosis diagnostics. The trial is registered at clinicaltrials.gov (NCT04089423).

Для цитирования: Székely Rita, Sossen Bianca, Mukoka Madalo, Muyoyeta Monde, Nakabugo Elizabeth, Hella Jerry, Nguyen Hung Van, Ubolyam Sasiwimol, Chikamatsu Kinuyo, Macé Aurélien, Vermeulen Marcia, Centner Chad M, Nyangu Sarah, Sanjase Nsala, Sasamalo Mohamed, Dinh Huong Thi, Ngo The Anh, Manosuthi Weerawat, Jirajariyavej Supunnee, Mitarai Satoshi, Nguyen Nhung Viet, Avihingsanon Anchalee, Reither Klaus, Nakiyingi Lydia, Kerkhoff Andrew D, MacPherson Peter, Meintjes Graeme, Denkinger Claudia M, Ruhwald Morten, FujiLAM Study Consortium. Prospective multicentre accuracy evaluation of the FUJIFILM SILVAMP TB LAM test for the diagnosis of tuberculosis in people living with HIV demonstrates lot-to-lot variability.. PloS one. 2024. DOI: 10.1371/journal.pone.0303846.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.