Three-year ear, nose, and throat cross-sectional analysis of audiometric protocols for magnetic resonance imaging screening of acoustic tumors.

Cheng Teddy Caramoan, Wareing Michael J

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

(1) Evaluate audiometric protocols and recommend protocols with best sensitivity and specificity for magnetic resonance imaging (MRI) screening of acoustic tumors; (2) determine clinical risks (false negative) of missing acoustic tumors and potential wastes in screening (false positive) nonacoustic tumors or radiologically "normal" cases; and (3) identify the decibel difference and range of frequencies compared by the best-performing protocols.

STUDY

DESIGN

Cross-sectional study with chart review.

SETTING

Ear, nose, and throat (ENT); audiology; and radiology departments in a tertiary-care hospital.

SUBJECTS AND

METHODS

Three-year cohort (2006-2009) of 1751 ENT patients underwent MRI screening and pure-tone audiometry indicating sensorineural hearing loss. Audiometric protocols were ranked by highest sensitivity to acoustic tumors, specificity A to nonacoustic tumors, and specificity B to "radiologically normal" cases.

RESULTS

No audiometric protocols achieved 100% sensitivity or specificity rates. Only 2 protocols achieved ≥90% sensitivity: the AMCLASS-A-Urben protocol (93.16%) and the Mangham protocol (91.58%). Eleven of 15 protocols for specificity A and 12 of 15 protocols for specificity B achieved ≥50%. Clinical risks ranged from 6.84% to 18.95%, whereas potential wastes ranged from 33.56% to 68.37% for specificity A and 31.76% to 66.86% for specificity B. Interaural difference parameters indicating highest mean sensitivity were on the order of ≥10 dB, ≥15 dB, and ≥20 dB. For frequency comparison parameters, "2 or more adjacent frequency" and "single-frequency" comparison indicated higher mean sensitivity than the "averaged multifrequency" comparison. Mean specificity showed an opposite pattern.

CONCLUSIONS

For optimum sensitivity, the Mangham protocol is preferred (sensitivity, 91.58%; specificity A, 44.23%; specificity B, 44.91%), which proposes a ≥10-dB interaural difference, averaging 1 to 8 kHz. For optimum specificity, the American Academy of Otolaryngology-Head and Neck Surgery protocol is preferred (sensitivity, 87.37%; specificity A, 65.38%; specificity B, 66.04%), which proposes ≥15 dB between ears, averaging 0.5 to 3 kHz.

Для цитирования: Cheng Teddy Caramoan, Wareing Michael J. Three-year ear, nose, and throat cross-sectional analysis of audiometric protocols for magnetic resonance imaging screening of acoustic tumors.. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2011. DOI: 10.1177/0194599811427384.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.