MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s2666-5247(24)00001-6

Медицинская библиотека · The Lancet. Microbe · 2024

Xpert MTB/RIF Ultra versus mycobacterial growth indicator tube liquid culture for detection of Mycobacterium tuberculosis in symptomatic adults: a diagnostic accuracy study.

Xie Yingda L, Eichberg Christie, Hapeela Nchimunya, Nakabugo Elizabeth, Anyango Irene, Arora Kiranjot, Korte Jeffrey E, Odero Ronald, van Heerden Judi, Zemanay Widaad, Kennedy Samuel, Nabeta Pamela, Hanif Mahmud, Rodrigues Camilla, Skrahina Alena, Stevens Wendy, Dietze Reynaldo, Liu Xin, Ellner Jerrold J, Alland David, Joloba Moses L, Schumacher Samuel G, McCarthy Kimberly D, Nakiyingi Lydia, Dorman Susan E

СтатьяМногоцентровое исследованиеСравнительное исследованиеПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND

Xpert MTB/RIF Ultra (Ultra) is an automated molecular test for the detection of Mycobacterium tuberculosis in sputum. We compared the sensitivity of Ultra to that of mycobacterial growth indicator tube (MGIT) liquid culture, considered the most sensitive assay in routine clinical use.

METHODS

In this prospective, multicentre, cross-sectional diagnostic accuracy study, we used a non-inferiority design to assess whether the sensitivity of a single Ultra test was non-inferior to that of a single liquid culture for detection of M tuberculosis in sputum. We enrolled adults (age ≥18 years) with pulmonary tuberculosis symptoms in 11 countries and each adult provided three sputum specimens with a minimum volume of 2 mL over 2 days. Ultra was done directly on sputum 1, and Ultra and MGIT liquid culture were done on resuspended pellet from sputum 2. Results of MGIT and solid media cultures done on sputum 3 were considered the reference standard. The pre-defined non-inferiority margin was 5·0%.

FINDINGS: Between Feb 18, 2016, and Dec 4, 2019, we enrolled 2906 participants. 2600 (89%) participants were analysed, including 639 (25%) of 2600 who were positive for tuberculosis by the reference standard. Of the 2357 included in the non-inferiority analysis, 877 (37%) were HIV-positive and 984 (42%) were female. Sensitivity of Ultra performed directly on sputum 1 was non-inferior to that of sputum 2 MGIT culture (MGIT 91·1% vs Ultra 91·9%; difference -0·8 percentage points; 95% CI -2·8 to 1·1). Sensitivity of Ultra performed on sputum 2 pellet was also non-inferior to that of sputum 2 MGIT (MGIT 91·1% vs Ultra 91·9%; difference -0·8 percentage points; -2·7 to 1·0).

INTERPRETATION: For the detection of M tuberculosis in sputum from adults with respiratory symptoms, there was no difference in sensitivity of a single Ultra test to that of a single MGIT culture. Highly sensitive, rapid molecular approaches for M tuberculosis detection, combined with advances in genotypic methods for drug resistance detection, have potential to replace culture.

FUNDING: US National Institute of Allergy and Infectious Diseases.

Для цитирования: Xie Yingda L, Eichberg Christie, Hapeela Nchimunya, Nakabugo Elizabeth, Anyango Irene, Arora Kiranjot, Korte Jeffrey E, Odero Ronald, van Heerden Judi, Zemanay Widaad, Kennedy Samuel, Nabeta Pamela, Hanif Mahmud, Rodrigues Camilla, Skrahina Alena, Stevens Wendy, Dietze Reynaldo, Liu Xin, Ellner Jerrold J, Alland David, Joloba Moses L, Schumacher Samuel G, McCarthy Kimberly D, Nakiyingi Lydia, Dorman Susan E. Xpert MTB/RIF Ultra versus mycobacterial growth indicator tube liquid culture for detection of Mycobacterium tuberculosis in symptomatic adults: a diagnostic accuracy study.. The Lancet. Microbe. 2024. DOI: 10.1016/s2666-5247(24)00001-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.