Accuracy of matching optic discs with visual fields: the European Structure and Function Assessment Trial (ESAFAT).

van der Schoot Josine, Reus Nicolaas J, Garway-Heath David F, Saarela Ville, Anton Alfonso, Bron Alain M, Faschinger Christoph, Holló Gábor, Iester Michele, Jonas Jost B, Topouzis Fotis, Zeyen Thierry G, Lemij Hans G

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the ability of ophthalmologists across Europe to match stereoscopic optic disc photographs to visual fields of varying severity.

DESIGN

Evaluation and comparison of 2 diagnostic tests.

PARTICIPANTS

A total of 109 of 260 invited ophthalmologists in 11 European countries. These had participated in the previous European Optic Disc Assessment Trial (EODAT), a trial on glaucoma diagnostic accuracy based on optic discs only.

METHODS

Each participant matched stereo optic disc photographs of 40 healthy and 48 glaucomatous eyes to a visual field chosen from 4 options per disc. The 4 presented visual fields included the corresponding one and 3 other visual fields, varying in severity. The matching accuracy and any inaccuracy per disease severity were calculated. Classification accuracy (as glaucomatous or healthy) was compared with EODAT data. Duplicate slides allowed for the assessment of intraobserver agreement.

MAIN OUTCOME MEASURES: Accuracy of matching optic discs with their corresponding visual field and of classifying them as healthy or glaucomatous; intraobserver agreement (κ).

RESULTS

The overall accuracy of ophthalmologists for correctly matching stereoscopic optic disc photographs to their visual fields was 58.7%. When incorrectly matched, the observers generally overestimated the visual field severity (P<0.001), notably in eyes with early glaucoma. The intraobserver agreement was, on average, moderate (0.52).

CONCLUSIONS

European ophthalmologists correctly matched stereoscopic optic disc photographs to their corresponding visual field in only approximately 59% of cases. In most mismatches, the clinicians overestimated the visual field damage.

Для цитирования: van der Schoot Josine, Reus Nicolaas J, Garway-Heath David F, Saarela Ville, Anton Alfonso, Bron Alain M, Faschinger Christoph, Holló Gábor, Iester Michele, Jonas Jost B, Topouzis Fotis, Zeyen Thierry G, Lemij Hans G. Accuracy of matching optic discs with visual fields: the European Structure and Function Assessment Trial (ESAFAT).. Ophthalmology. 2013. DOI: 10.1016/j.ophtha.2013.05.026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.