MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bjo.2008.149963

Медицинская библиотека · The British journal of ophthalmology · 2008

The association between retinal vein ophthalmodynamometric force change and optic disc excavation.

Morgan W H, Hazelton M L, Balaratnasingamm C, Chan H, House P H, Barry C J, Cringle S J, Yu D-Y

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIM: Retinal vein ophthalmodynamometric force (ODF) is predictive of future optic disc excavation in glaucoma, but it is not known if variation in ODF affects prognosis. We aimed to assess whether a change in ODF provides additional prognostic information.

METHODS

135 eyes of 75 patients with glaucoma or being glaucoma suspects had intraocular pressure (IOP), visual fields, stereo optic disc photography and ODF measured on an initial visit and a subsequent visit at mean 82 (SD 7.3) months later. Corneal thickness and blood pressure were recorded on the latter visit. When venous pulsation was spontaneous, the ODF was recorded as 0 g. Change in ODF was calculated. Flicker stereochronoscopy was used to determine the occurrence of optic disc excavation, which was modelled against the measured variables using multiple mixed effects logistic regression.

RESULTS

Change in ODF (p = 0.046) was associated with increased excavation. Average IOP (p = 0.66) and other variables were not associated. Odds ratio for increased optic disc excavation of 1.045 per gram ODF change (95% CI 1.001 to 1.090) was calculated.

CONCLUSION

Change in retinal vein ODF may provide additional information to assist with glaucoma prognostication and implies a significant relationship between venous change and glaucoma patho-physiology.

Для цитирования: Morgan W H, Hazelton M L, Balaratnasingamm C, Chan H, House P H, Barry C J, Cringle S J, Yu D-Y. The association between retinal vein ophthalmodynamometric force change and optic disc excavation.. The British journal of ophthalmology. 2008. DOI: 10.1136/bjo.2008.149963.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.