Value of retinal vein pulsation characteristics in predicting increased optic disc excavation.
Аннотация
BACKGROUND
Retinal vein pulsation is often absent in glaucoma, but can be induced by applying a graded ophthalmodynamometric force (ODF) to the eye, which is elevated in glaucoma.
AIM: To assess whether ODF has a predictive value in determining glaucoma progression.
METHODS
75 patients with glaucoma and suspected glaucoma were examined prospectively in 1996, and then re-examined at a mean of 82 months later. All subjects had intraocular pressure, visual fields, stereo optic disc photography and ODF measured on their initial visit. When venous pulsation was spontaneous, the ODF was said to be 0 g. At re-examination, central corneal thickness and blood pressure were also measured. Initial and subsequent optic disc photographs were compared and graded into those that had increased excavation and those that had remained stable. The relationship between increased excavation (recorded as a binary response) and the measured variables was modelled using a multiple mixed effects logistic regression.
RESULTS
ODF at the initial visit was strongly predictive of increased excavation (p = 0.004, odds ratio 1.16/g, range 0-60 g), with greater predictive value in women than in men (p = 0.004). Visual field mean deviation was predictive of increased excavation (p = 0.044), as was optic nerve haemorrhage in association with older age (p = 0.038). Central corneal thickness was not significantly predictive of increased excavation (p = 0.074) after having adjusted for other variables.
CONCLUSION
ODF measurement seems to be strongly predictive of the patient's risk for increased optic disc excavation. This suggests that ODF measurement may have predictive value in assessing the likelihood of glaucoma progression.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.