DOI 10.1016/s0161-6420(02)01100-4

Медицинская библиотека · Ophthalmology · 2002

Detection of optic neuropathy in glaucomatous eyes with normal standard visual fields using a test battery of short-wavelength automated perimetry and pattern electroretinography.

Bayer Andreas U, Maag Klaus-Peter, Erb Carl

Клиническое исследованиеСравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the clinical use of a test battery of short-wavelength automated perimetry (SWAP), frequency-doubling technology (FDT) perimetry, and pattern-electroretinography (PERG) in patients with definite primary open-angle glaucoma (POAG) but normal results on standard automated perimetry (SAP).

STUDY

DESIGN

Prospective, comparative, observational case series.

PARTICIPANTS

Thirty-six patients with POAG with standard visual field defects in one eye and normal standard visual fields in the contralateral eye and 36 normal controls were enrolled.

MAIN OUTCOME MEASURES: SWAP, PERG, FDT, and SAP were performed in all eyes, and global indices and amplitudes were used for statistical analysis.

RESULTS

When contralateral POAG eyes with asymmetric glaucomatous damage was compared, a paired t test showed significant differences in SAP mean deviation (MD) (P < 0.0001), SWAP-MD (P = 0.0003), FDT-MD (P = 0.0008), and PERG amplitudes (P < 0.0001). When comparing between POAG eyes with normal results on SAP and normal controls, Student's t test showed significant differences for SWAP-MD (P < 0.0001), FDT-MD (P = 0.0006), PERG N1P1-amplitude (P = 0.0486) and P1N2-amplitude (P < 0.0001); receiver operating characteristic analysis revealed promising accuracy for SWAP-MD of 73.6% (P < 0.0001). SWAP-MD (P < 0.0001) and FDT-MD (P < 0.0001) correlated significantly with SAP-MD and with each other (range, P < 0.0001 to P = 0.0020). Regression analysis revealed that PERG P1N2-amplitude could improve the power of SWAP-MD from 73.6% to detect early POAG in eyes with normal results on SAP to an accuracy of 81.9%.

CONCLUSIONS

A test battery of SWAP-MD and PERG P1N2-amplitude could detect glaucomatous optic neuropathy in POAG eyes with normal standard visual fields, whereas FDT-MD and SWAP-MD significantly correlated with each other and with SAP-MD. All tests were able to detect the eye with the more severe glaucomatous optic neuropathy in patients with asymmetric POAG.

Для цитирования: Bayer Andreas U, Maag Klaus-Peter, Erb Carl. Detection of optic neuropathy in glaucomatous eyes with normal standard visual fields using a test battery of short-wavelength automated perimetry and pattern electroretinography.. Ophthalmology. 2002. DOI: 10.1016/s0161-6420(02)01100-4.