MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1056/nejmoa052367

Медицинская библиотека · The New England journal of medicine · 2006

Multidetector computed tomography for acute pulmonary embolism.

Stein Paul D, Fowler Sarah E, Goodman Lawrence R, Gottschalk Alexander, Hales Charles A, Hull Russell D, Leeper Kenneth V, Popovich John, Quinn Deborah A, Sos Thomas A, Sostman H Dirk, Tapson Victor F, Wakefield Thomas W, Weg John G, Woodard Pamela K, PIOPED II Investigators

Оценочное исследованиеСтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

BACKGROUND

The accuracy of multidetector computed tomographic angiography (CTA) for the diagnosis of acute pulmonary embolism has not been determined conclusively.

METHODS

The Prospective Investigation of Pulmonary Embolism Diagnosis II trial was a prospective, multicenter investigation of the accuracy of multidetector CTA alone and combined with venous-phase imaging (CTA-CTV) for the diagnosis of acute pulmonary embolism. We used a composite reference test to confirm or rule out the diagnosis of pulmonary embolism.

RESULTS

Among 824 patients with a reference diagnosis and a completed CT study, CTA was inconclusive in 51 because of poor image quality. Excluding such inconclusive studies, the sensitivity of CTA was 83 percent and the specificity was 96 percent. Positive predictive values were 96 percent with a concordantly high or low probability on clinical assessment, 92 percent with an intermediate probability on clinical assessment, and nondiagnostic if clinical probability was discordant. CTA-CTV was inconclusive in 87 of 824 patients because the image quality of either CTA or CTV was poor. The sensitivity of CTA-CTV for pulmonary embolism was 90 percent, and specificity was 95 percent. CTA-CTV was also nondiagnostic with a discordant clinical probability.

CONCLUSIONS

In patients with suspected pulmonary embolism, multidetector CTA-CTV has a higher diagnostic sensitivity than does CTA alone, with similar specificity. The predictive value of either CTA or CTA-CTV is high with a concordant clinical assessment, but additional testing is necessary when the clinical probability is inconsistent with the imaging results.

Для цитирования: Stein Paul D, Fowler Sarah E, Goodman Lawrence R, Gottschalk Alexander, Hales Charles A, Hull Russell D, Leeper Kenneth V, Popovich John, Quinn Deborah A, Sos Thomas A, Sostman H Dirk, Tapson Victor F, Wakefield Thomas W, Weg John G, Woodard Pamela K, PIOPED II Investigators. Multidetector computed tomography for acute pulmonary embolism.. The New England journal of medicine. 2006. DOI: 10.1056/nejmoa052367.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.