Evaluation of the deep venous system in patients with suspected pulmonary embolism with multi-detector CT: a prospective study in comparison to Doppler sonography.

Begemann Philipp G C, Bonacker Michael, Kemper Jörn, Guthoff Angelika E, Hahn Kyungja E, Steiner Paul, Adam Gerhard

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

This prospective study was done to evaluate the ability of indirect multidetector row CT venography (CTV) in detecting deep venous thrombosis of the pelvis and the thighs in comparison with Doppler sonography in patients with suspected pulmonary embolism (PE).

METHODS

Forty-one patients with suspected PE were included, and CTV (collimation 4 x 2.5 mm, table feed 12.5 mm, 120 kV, eff. mAs 165) from the iliac crest to the knees was done after CT angiography (CTA) of the pulmonary arteries. Doppler sonography was performed within 24 hours. Applied radiation doses were estimated using the PC program WinDose.

RESULTS

PE was diagnosed in 20 patients with additional DVT in 11 patients. The CTV has a sensitivity of 100%, specificity of 96.6%, a positive and negative predictive value of 91.7% and 100%, respectively. The median cumulative effective dose for CTV was 8.26 mSv with a gonadal dose of 3.87 mSv. Changing the CTV protocol to a collimation of 4 x 5 mm with a 25 mm table feed could reduce the dose by approximately 11% (p < 0.05) to 7.25 mSv and 3.35 mSv, respectively.

CONCLUSION

CTV is a safe and quick diagnostic tool for detecting DVT in patients with suspected PE. Due to the relevant increase in radiation dose, the indication has to be considered very carefully.

Для цитирования: Begemann Philipp G C, Bonacker Michael, Kemper Jörn, Guthoff Angelika E, Hahn Kyungja E, Steiner Paul, Adam Gerhard. Evaluation of the deep venous system in patients with suspected pulmonary embolism with multi-detector CT: a prospective study in comparison to Doppler sonography.. Journal of computer assisted tomography. 2003. DOI: 10.1097/00004728-200305000-00017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.