Reproducibility of flap thickness in sub-Bowman keratomileusis using a mechanical microkeratome.

Althomali Talal Abdulrahman

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To examine the predictability of flap thickness using a mechanical microkeratome (One Use-Plus) and identify factors related to variations in flap thickness in sub-Bowman keratomileusis (SBK).

SETTING

Tadawi Surgical Center, Taif, Saudi Arabia.

DESIGN

Retrospective case series.

METHODS

Patients with a stable refraction for 1 year, corrected distance visual acuity (CDVA) of at least 20/20 in each eye, and minimum central corneal thickness of 480 μm in each eye had microkeratome-assisted SBK. Parameters included manifest refraction, uncorrected distance visual acuity (UDVA), CDVA, pachymetry, and higher-order aberrations (HOAs).

RESULTS

Seventy eyes (36 patients) were enrolled. The mean flap thickness was 88.74 μm ± 15.40 (SD) and the mean change in HOAs, 0.11 ± 0.30 μm(2). There was no correlation between flap thickness and age (r = -0.10), preoperative manifest refraction spherical equivalent (MRSE) (r = -0.08), preoperative cylinder (r = 0.13), postoperative CDVA (r = -0.17), or postoperative change in HOAs (r = -0.07). A strong positive correlation with preoperative pachymetry (r = 0.41) and a weak negative correlation with preoperative sphere (r = -0.21) were observed. There was no or a moderate negative correlation of pachymetry with age (r = -0.14), preoperative sphere (r = -0.36), cylinder (r = -0.04), or MRSE (r = -0.36).

CONCLUSIONS

The microkeratome was reliable with reasonable predictability for SBK flap creation. Extra caution in handling the flaps to avoid flap striae or tears is advised. Flap thickness correlated positively with preoperative pachymetry; however, the variation in flap thickness did not affect visual outcomes.

FINANCIAL DISCLOSURE: The author has no financial or proprietary interest in any material or method mentioned.

Для цитирования: Althomali Talal Abdulrahman. Reproducibility of flap thickness in sub-Bowman keratomileusis using a mechanical microkeratome.. Journal of cataract and refractive surgery. 2014. DOI: 10.1016/j.jcrs.2014.02.046.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.