MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcrs.2014.01.036

Медицинская библиотека · Journal of cataract and refractive surgery · 2014

Fourier-domain optical coherence tomography evaluation of clear corneal incision structure according to blade material.

Lee Hun, Kim Eung Kweon, Kim Hong Seok, Kim Tae-Im

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To use Fourier-domain optical coherence tomography (OCT) to evaluate the wound characteristics of clear corneal incisions (CCIs) created with a metal or diamond blade in cataract surgery.

SETTING

Department of Ophthalmology, Institute of Vision Research, Yonsei University College of Medicine, Seoul, South Korea.

DESIGN

Prospective comparative observational study.

METHODS

Patients who had cataract surgery were randomized into 2 groups based on whether a metal blade (Group 1, 37 eyes) or diamond blade (Group 2, 33 eyes) was used to create a 2.8 mm temporal CCI. One day, 1 week, and 1 month postoperatively, structural characteristics of the CCI were analyzed using RTVue-100 Fourier-domain OCT. Parameters included incision angle, corneal thickness, epithelial or endothelial gaps, and Descemet membrane detachment. Visual acuity, surgically induced astigmatism (SIA), and ocular aberrations were evaluated.

RESULTS

There was a significant difference in corneal thickness at the 1.0 mm temporal side from midpoint. The mean uncorrected distance visual acuity in Group 2 (33 eyes) improved significantly over time. In both groups, corneal thickness at the midpoint, 1.0 mm temporal side, and 1.0 mm nasal side from the midpoint of the incision significantly decreased over time. At all timepoints, temporal and nasal thickness in Group 2 was significantly greater than in Group 1 (37 eyes), with the exception of temporal thickness at 1 month. In both groups, wound healing was reliable over time. There were no significant between-group differences in SIA or changes in aberrations.

CONCLUSIONS

Corneal thickness at the incision site showed a significant difference between the 2 groups. Both groups achieved structural stabilization.

FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.

Для цитирования: Lee Hun, Kim Eung Kweon, Kim Hong Seok, Kim Tae-Im. Fourier-domain optical coherence tomography evaluation of clear corneal incision structure according to blade material.. Journal of cataract and refractive surgery. 2014. DOI: 10.1016/j.jcrs.2014.01.036.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.