MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0b013e318200099d

Медицинская библиотека · Cornea · 2011

In vivo laser confocal microscopy findings of Thygeson superficial punctate keratitis.

Kobayashi Akira, Yokogawa Hideaki, Sugiyama Kazuhisa

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: We looked for microstructural corneal characteristics of Thygeson superficial punctate keratitis (TSPK) in an in vivo investigation using laser scanning confocal microscopy.

METHODS

Five patients (3 men and 2 women; mean age, 51.8 years) with clinically diagnosed TSPK were enrolled in this study. All patients were examined by slit-lamp biomicroscopy and in vivo laser confocal microscopy. Deposits in selected confocal images of all corneal layers were evaluated qualitatively for shape and degree of light reflection.

RESULTS

The most characteristic finding was aggregates of highly reflective deposits with a starburst-like appearance that corresponded with epithelial punctate lesions identified by slit-lamp biomicroscopy; the aggregates were sporadically observed in all cases at the superficial and basal epithelial cell layers. Subepithelial haze was observed in all cases. Langerhans cells were also sporadically observed in all cases at the basal epithelial layer. Bowman layer abnormalities were observed in 3 of 5 cases; all these patients had a long history of TSPK (eg, more than 1 year). In addition, the 3 patients had highly reflective, tiny, needle-shaped materials in the corneal stroma.

CONCLUSIONS

In vivo laser confocal microscopy is capable of identifying characteristic corneal microstructural changes related to TSPK with a higher resolution than is available with slit-lamp biomicroscopy. It may also be a valuable tool for further research to elucidate both pathogenesis and the natural course of TSPK.

Для цитирования: Kobayashi Akira, Yokogawa Hideaki, Sugiyama Kazuhisa. In vivo laser confocal microscopy findings of Thygeson superficial punctate keratitis.. Cornea. 2011. DOI: 10.1097/ico.0b013e318200099d.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.