MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1365-2222.2004.02045.x

Медицинская библиотека · Clinical and experimental allergy : journal of the British Society for Allergy and Clinical Immunology · 2004

Analysis of effector and regulatory immune reactivity to nickel.

Rustemeyer T, von Blomberg B M E, van Hoogstraten I M W, Bruynzeel D P, Scheper R J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Diagnostic patch testing in allergic contact dermatitis faces the risk of boosting existing hypersensitivities or active sensitization. Risk-free and reliable in vitro assays using peripheral blood are, therefore, wanted.

OBJECTIVES

Here, we studied new approaches for in vitro monitoring of nickel-specific effector ad regulatory cell functions in allergic patients and potentially tolerized individuals.

METHODS

Lymphocyte proliferation assays were carried out with the allergen and additional IL-12/IL-7 or IL-4/IL-7 cytokine supplements. Release of IFN-gamma and IL-5 were assessed as measures for type-1 and type-2 effector T cell function, respectively, and IL-10 and TGF-beta1 to monitor possible regulatory T cell function reflecting immunological tolerance. After optimization of in vitro cut-off values, potency of these parameters was evaluated as compared with conventional nickel patch testing.

RESULTS

One hundred and fifty six outpatients were included in this study, 74 of whom presenting with a positive history of nickel allergy. Nickel-sulphate patch test results showed positive reactions in 43 patients, of whom 40 had a positive history (test sensitivity 54%; specificity 96%; overall accuracy 76%). Proliferation tests without cytokine supplementation showed an accuracy of 68%, which was further improved by supplementing IL-4/IL-7 (82%). IFN-gamma and IL-5 cytokine production, as revealed in IL-12/IL-7 and IL-4/IL-7 supplemented cultures, respectively, showed accuracies of 70% and 83%. As to the production of putatively immunoregulatory cytokines, IL-10 was most informative, with highest production rates in nickel-skin test negative individuals with long-lasting mucosal metal contact preceding skin piercing.

CONCLUSIONS

These results indicate that measuring both T cell proliferation and cytokine secretion profiles, in particular IL-5 release using IL-4/IL-7 supplemented medium, offers a promising improvement of the in vitro diagnostic options in monitoring nickel contact sensitization. Since oral nickel contact has been shown earlier to induce active tolerization, nickel-induced in vitro IL-10 production may help identify nickel-tolerized individuals.

Для цитирования: Rustemeyer T, von Blomberg B M E, van Hoogstraten I M W, Bruynzeel D P, Scheper R J. Analysis of effector and regulatory immune reactivity to nickel.. Clinical and experimental allergy : journal of the British Society for Allergy and Clinical Immunology. 2004. DOI: 10.1111/j.1365-2222.2004.02045.x.