MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/ryct.230124

Медицинская библиотека · Radiology. Cardiothoracic imaging · 2023

Artificial Intelligence-based Coronary Stenosis Quantification at Coronary CT Angiography versus Quantitative Coronary Angiography.

Dundas James, Leipsic Jonathon A, Sellers Stephanie, Blanke Philipp, Miranda Patricia, Ng Nicholas, Mullen Sarah, Meier David, Akodad Mariama, Sathananthan Janarthanan, Collet Carlos, de Bruyne Bernard, Muller Olivier, Tzimas Georgios

СтатьяПеревод пока не подготовлен

Аннотация

Purpose To evaluate the performance of a new artificial intelligence (AI)-based tool by comparing the quantified stenosis severity at coronary CT angiography (CCTA) with a reference standard derived from invasive quantitative coronary angiography (QCA). Materials and Methods This secondary, post hoc analysis included 120 participants (mean age, 59.7 years ± 10.8 [SD]; 73 [60.8%] men, 47 [39.2%] women) from three large clinical trials (AFFECTS, P3, REFINE) who underwent CCTA and invasive coronary angiography with QCA. Quantitative analysis of coronary stenosis severity at CCTA was performed using an AI-based coronary stenosis quantification (AI-CSQ) software service. Blinded comparison between QCA and AI-CSQ was measured on a per-vessel and per-patient basis. Results The per-vessel AI-CSQ diagnostic sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were 80%, 88%, 86%, 65%, and 94%, respectively, for diameter stenosis (DS) 50% or greater; and 78%, 92%, 91%, 47%, and 98%, respectively, for DS 70% or greater. The areas under the receiver operating characteristic curve (AUCs) to predict DS of 50% or greater and 70% or greater on a per-vessel basis were 0.92 (95% CI: 0.88, 0.95; P < .001) and 0.93 (95% CI: 0.89, 0.97; P < .001), respectively. The AUCs to predict DS of 50% or greater and 70% or greater on a per-patient basis were 0.93 (95% CI: 0.88, 0.97; P < .001) and 0.88 (95% CI: 0.81, 0.94; P < .001), respectively. Conclusion AI-CSQ at CCTA demonstrated a high diagnostic performance compared with QCA both on a per-patient and per-vessel basis, with high sensitivity for stenosis detection. Keywords: CT Angiography, Cardiac, Coronary Arteries Supplemental material is available for this article. Published under a CC BY 4.0 license.

Для цитирования: Dundas James, Leipsic Jonathon A, Sellers Stephanie, Blanke Philipp, Miranda Patricia, Ng Nicholas, Mullen Sarah, Meier David, Akodad Mariama, Sathananthan Janarthanan, Collet Carlos, de Bruyne Bernard, Muller Olivier, Tzimas Georgios. Artificial Intelligence-based Coronary Stenosis Quantification at Coronary CT Angiography versus Quantitative Coronary Angiography.. Radiology. Cardiothoracic imaging. 2023. DOI: 10.1148/ryct.230124.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.