MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/tuffc.2023.3345740

Медицинская библиотека · IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2024

Automatic Diagnosis of Carotid Atherosclerosis Using a Portable Freehand 3-D Ultrasound Imaging System.

Li Jiawen, Huang Yunqian, Song Sheng, Chen Hongbo, Shi Junni, Xu Duo, Zhang Haibin, Chen Man, Zheng Rui

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The objective of this study is to develop a deep-learning-based detection and diagnosis technique for carotid atherosclerosis (CA) using a portable freehand 3-D ultrasound (US) imaging system. A total of 127 3-D carotid artery scans were acquired using a portable 3-D US system, which consisted of a handheld US scanner and an electromagnetic (EM) tracking system. A U-Net segmentation network was first applied to extract the carotid artery on 2-D transverse frame, and then, a novel 3-D reconstruction algorithm using fast dot projection (FDP) method with position regularization was proposed to reconstruct the carotid artery volume. Furthermore, a convolutional neural network (CNN) was used to classify healthy and diseased cases qualitatively. Three-dimensional volume analysis methods, including longitudinal image acquisition and stenosis grade measurement, were developed to obtain the clinical metrics quantitatively. The proposed system achieved a sensitivity of 0.71, a specificity of 0.85, and an accuracy of 0.80 for diagnosis of CA. The automatically measured stenosis grade illustrated a good correlation ( r = 0.76) with the experienced expert measurement. The developed technique based on 3-D US imaging can be applied to the automatic diagnosis of CA. The proposed deep-learning-based technique was specially designed for a portable 3-D freehand US system, which can provide a more convenient CA examination and decrease the dependence on the clinician's experience.

Для цитирования: Li Jiawen, Huang Yunqian, Song Sheng, Chen Hongbo, Shi Junni, Xu Duo, Zhang Haibin, Chen Man, Zheng Rui. Automatic Diagnosis of Carotid Atherosclerosis Using a Portable Freehand 3-D Ultrasound Imaging System.. IEEE transactions on ultrasonics, ferroelectrics, and frequency control. 2024. DOI: 10.1109/tuffc.2023.3345740.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.